HVAC: Generac Generator | Gas Line Install

preview_player
Показать описание
Thank You please Like & Subscribe
Рекомендации по теме
Комментарии
Автор

I suggest using a second wrench to stabilize the fixed side of the piping when torqueing down. Otherwise you risk breaking something.

benbrown
Автор

Not just basic low baller adjustables but Knipex Pliers Wrench, big baller tools.

muniznick
Автор

👏🏽I havne't run out of your videos yet!💜👍🏽#81

Leenie
Автор

Ooh ah push it ooh ah push it real good. Salt N Peppa where talking pipe dope lol

kevinlewis
Автор

Your work is nice and efficient, seems you have knowledge in everything. Want to Come work for me.

commercialmechanical
Автор

I was wondering why if your using csst gas pipe would you still need the flexible gas pipe. We use steel pipe all the way to meter looks better, yet csst installs faster and proven to function just as good. Yet the flexible line is just a vibration damper, when using rigid steel pipe. Yet csst can handle vibration. Is it local code? Generac gives the option of using. Yet it does help with final connection

thehvachacker
Автор

I’m worried about a natural gas line I ran for a generac 24k generator. I ran a 1” pipe and the generator is like about 60’ away from the meter. The worst part is that they poured a sidewalk over the gas line. I have a feeling it will be fine but I’m still worried. I don’t even want to connect this thing, don’t have the experience working with generators, I just do plumbing.

ZRTerror
Автор

Get you some knee pads buddy. You’ll thank me when you get my age. Good vid!

zapservices
Автор

What about you flood out what good is it setting on ground.. I have mine setting 7 feet off ground

Rigandfixit
Автор

I didn't think you were supposed to use CSST outside, just a question. any help would be greatly appreciated, thanks.

RodEvens
Автор

What is the brand name of the outdoor yellow flexible gas line?

jerrellstrawn
Автор

Looks good. I am probably going to get a Generac 24KW. Do you know what is a fair price range to have a certified contractor run the gas line from the generator to the gas meter? It will be anywhere from 7--8 ft between the generator and my gas meter? What important question(s) should I ask the contractor when he is running the gas line? I live in GA.

coreypatterson
Автор

What brand of pliers is that you're using. I've never seen a pair with no teeth! I'd like to grab a pair! Thanks

danielsoroken
Автор

I realize this may be a dumb question but why can’t you use the flexible line the whole way?

roberthomes
Автор

Is there a code for how many feet the Gas meter should be from the Generator? Thanks

bluv
Автор

How did u size it? Longest run method? If so did u the line in the house? To get Longest run

trackerify
Автор

I thought you aren’t supposed to Teflon gas pipe, because it could clog

sumolax
Автор

Hey use black lettering the blue is hard to see

sixshooter
Автор

Is a secondary regulator necessary before the unit. I'm using a 2# meter with an 85 ft. run between them. The installer put one in and my unit won't run.

drobhulse
Автор

Can I run 3/4 20 ft to unit? Or do I need 2 inch?

danielgoodheim