How To: Repair a Diverter Valve

preview_player
Показать описание

SUBSCRIBE for FREE pool care and maintenance videos

Listen to the Poolside Chat podcast!

With time the handle or shaft of your Diverter Valve might break or you may want to change out an older standard Valve Assembly for a Never Lube Valve Assembly. Also your Diverter Valve may be tightly integrated in your piping system to the point where you would have to replace multiple valves to replace a bad one. Fortunately most damaged valves can be repaired by replacing the valve assembly inside the Valve as an easier alternative to cutting out the whole valve. This guide shows you how to replace the Diverter Valve Assembly in a Diverter Valve.

To view this guide step by step on our website, visit:
Рекомендации по теме
Комментарии
Автор

Used this info to replace o-rings on a leaking diverter valve. Thanks. You saved me a bunch of money.

lrooff
Автор

Great video. Was able to replace my seals in four Pentair valves in less than one hour. Saved me $$$!

Formizzle
Автор

A no-nonsense video and to the point. Thank you.

bobmartin
Автор

1. Order diverter valve parts.
2. Turn off power.
3. Relieve system pressure.
4. Remember valve setting. (Note operational position of the handle.)
5. Remove handle lock knob.
6. Note position of inlet label.
7. Remove cover screws.
8. Pry off valve cover.
9. Note position of diverter paddle.
10. Push out diverter.
11. Remove cover O-ring.
12. Clean valve cover.
13. Slide O-rings on new diverter. (And replace cover O-ring. Lubricate all O-rings. Slide diverter shaft into cover.)
14. Rotate diverter to match old position (Position as noted in step 9).
15. Insert assembly into housing. (Position as noted in step 6)
16. Replace cover screws.
17. Place handle on valve shaft (Position as noted in step 4).

joehoch
Автор

Thanks, Great Video, one recommendation. When replacing the cover screws into the plastic housing. Push lightly while turning them counter clockwise till you feel a click. Then tighten the screws. This way you will not start a new set of treads which can lead to them stripping out. Also a lot easier to install the screws in the old threads than making new ones.

qwk
Автор

Thank you very much for this video. I replaced the o-rings and lubed them and that stopped the leak. I had to use a very sharp pocket knife to be able to separate the valve cover from the valve because the chisel or flat head screw driver didn't work.

JaguarViking
Автор

Thank you for sharing this informative video

alejandro
Автор

Very thorough and helpful. Thank you!

bjweaver
Автор

This worked for me and saved me hundreds of $$$$. Thanks

sandeep_karanjkar
Автор

Do NOT use a screwdriver or anything to pry apart, you will create a notch in the plastic housing since it is soft, this could create a leak. instead, re attach the handle and then carefully/slowly wiggle it off

firepelayo
Автор

Great advice. I figured out most of this on my own, but skipped the step of noting the original position of the cover - and there's no easy way with my pool to tell which incoming pipe is the inlet. So had to do the re-install twice. Suggest writing "inlet" on the appropriate pipe to avoid this problem.

perelmanfan
Автор

Getting a leak thru my waterfall. I suspect its coming from the valve key not sealing off the waterfall completely. What is the solution? Do i just buy the valve key or do i need to buy Orings as well?

domiannitti
Автор

Opened my diverter up to clean out a blockage (leaves) and my pump's pressure was instantly restored! Then it stopped working properly again quickly after. Now the lost pressure issue is widespread, affecting main drain as well (completely bypassing the earlier blocked pipes). Any chance I could get a tip of what to check next?

MarkMassengale
Автор

How can you tell if the leak is from the o ring needing to be replaced versus the entire valve needing to be replaced?

ripleyjustice
Автор

any advice for a whirlpool at pool drain

saifeldientarek
Автор

My pump stopped working and pool store told metro move diverter to where it doesn't go. So I got it there and now I can't get it back to normal. It won't turn. Should I get plyers and force the handle? Or take the thing apart? I'm new and nothing wrong with diverter valve. Was trying to get into impellor and check debris.

brysonslife
Автор

I do this once/ year for my solar diverter valve since it goes back and forth all year long. They leak like clockwork ever 12 months. I just replace the orings and there you go.

TonyEden
Автор

If you have a Pentair valve - Pentair exploded diagram of their valve on their web site shows a small spacer that goes between the 2 small o-rings that go onto the shaft. I just did mine and sure enough, there is a spacer.

penguinbriar
Автор

I replaced diverter but still leaking a little. It's better, but not off. ???

elkbass
Автор

what about the valve with 24v motor? calibration for not to get the water pased