NOTE: FOR ECONOMIC PURPOSES, YOU CAN USE DIFFERENT COMMERCIALLY AVAILABLE LENGTH OF RSB SO AS TO REDURE WASTAGE. Just replace the 6m length of RSB in the computation by the different available sizes - 6m, 7.5m, 9m, 10.5m, 12m.
Рекомендации по теме
Комментарии
Автор

14:20 Sir, very important po malaman ang most economical commercial length dahil pwedeng malaki po ang waste sa bakal kapag namali ng pagpili ng commercial length. Sa example niyo po, 3.60m ang magiging total waste kapag 6m com length ang ginamit pero kapag 9m com length, 0.60m lang po ang masasayang.

jesonrepana
Автор

Keep posting this kind of video po, it will help our young engineers a lot. Thanks po.

artcancer
Автор

malinaw at madaling intindihin..Salamat Sir

romeoselga
Автор

thanks for a very informative estimating tutorials Engineer. I hope you have to re-upload this with separate topic so that it will not be a very long video, , , i am sure also you will get more viewers.... keep it up and hoping for more informative and educational videos.

xbyyyx
Автор

WOW napaka liwanag nyo po mag explain sir. keep it up po

B-artdesign
Автор

salamat po maam. galing mo magpaliwanag very clear. pahinig kmi ng copya templete mo

rajiv
Автор

paano po pag may footing tie beam? Ganyan din po ba ang pag lagay sa mga lateral ties sa ground floor column?

cabroncito
Автор

Ang galing nyo po magturo at mag explain. Pwede po bang manghingi ng copy ng mga sheets ng schedule na gingamit mo? Thanks.

mountainrock
Автор

Sir pwd sa floor and roof framing din po.❤

LawrenceGotgot
Автор

Can you share the PDF file. Really appreciate that

adamhrsikesa
Автор

Engr. ask ko lang po paano po nakuha yung 0.1 na hook 49:10

johnchristophercaturan
Автор

This vid is a big help for me Thankyou!

nickieteves
Автор

Length of beam beam continous top and bottom, bakit po magkaiba?

kennethabrigo
Автор

Engineer paano mag-estimate ng RSB ng tie beam

yongchu
Автор

What reference did you use for the tables you provided at your presentation? Thank you!

joehight
Автор

sir paano po kung ang cuts value ay 4.94 cuts? whole number pa rin po ba? Thank you po

ricafayenicolemiraflores
Автор

Sir for clarification po at 1:27:15 sa column width po, isang 0.4 lang po ba talaga iaadd? Thank you po, your video is very helpful po

graceperez
Автор

Sr Cutting list sa footing.maraming waste .7 malaki n po yan klaro na 10.5 length gmitin walang tapon.

ihinyero
Автор

Sir, pdf po please baka meron yan. Helps a lot tlga sir

richojmondejar
Автор

i need earthworks and concrete detailed estimates :(