How to properly test a contactor

preview_player
Показать описание
This tutorial teaches you how to properly test a contactor.
Рекомендации по теме
Комментарии
Автор

Thanks for the video. I tested the continuity on the contractor on one side and didn't get a reading. Then tested the other side and it was good, so I went back to the bad side and tried pushing in a few more times and finally got a reading. Then tested the coil on ohms and it went up to 36. The conclusion is the contractor has badly worn contacts and with a somewhat shorted coil.

fatfroggy
Автор

Thanks, you made me look good at work.

LCAC
Автор

Thank you very much great tutorial on testing the coil and the contactor.

mattthompson
Автор

Thanks for the help; hopefully I can get my friend's industrial mixer diagnosed, now :)

Morboeatspeople
Автор

Im sorry im late but where was this while I was going to school yall still have any left ?

prettycureforever
Автор

check low voltage coming from furnace/pressure switch es

josecoreas
Автор

Hella this just helped me do my service call HVAC life

carlossolar
Автор

Does it matter where's the top or bottom for the voltage lines (main power)?

nsfr
Автор

So on continuity mine reads 000 or 001 and stays and beeps

jacobwatkins
Автор

There ain't no app for that?
The cards, that is

CaseyMillerhome
Автор

Sir plz first say lay kar end tak underground piping say wiring ka trika bta dien plz

waqaschwaqas
Автор

THIS IS NOT THE PROPER WAY TO TEST A CONTACTOR, ALTHOUGH THIS WILL GIVE YOU SOME INFO, A CONTACTOR MUST ALSO BE TESTED UNDER LOAD. JUST BECAUSE THE CONTACOR CLOSES AND EVERYTHING COMES ON YOU COULD STILL HAVE VOLTAGE DROP OR A INCREASE IN AMPERAGE ACROSS THE CONTACTS. AND TOOLS ARE ONLY AS GOOD AS THE PERSON USING THEM NOT THE OTHER WAY AROUND. FOR AN EXAMPLE WATCH THE ABOVE VIDEO OF A SALESMAN PLAYING THE PART OF A TECH. NOTHING AGAINST THE SALESMAN HE DID MAKE A GOOD PRESENTATION. AS A STATE LICENSED HVAC CONTRACTOR WITH 37 YEARS IN THE TRADE I HAVE CHANGED MORE WORN CONTACTORS THAN FAILED ONES. CONTACTORS, CAPACITORS, AND BATTERIES SHOULD BE CHECKED UNDER LOAD. NOT WHEN THEY ARE IDLE.

hvacmike
Автор

what is the resistance of the contact if we measure from L1 to T1?

janitourmeneta
Автор

I'll use Inplix instructions to make it by myself.

vladklimovich
Автор

hi there,
ive changed the cotactor and capacitor but still ac is not working. there is no buzzing sound or nothing.its dead. but when i press the contactor it works.
please help.

nb
Автор

In my day, we didnt have all these fancy dancy capacitor testers.

tspriggsabq
Автор

Far to basic test, no good in the real field. Nice try.

reltonhome