Efficiency Of Lap Joint | Problem 2 | Bolted Connection | Design Of Steel Structures

preview_player
Показать описание
Hello Friends!!
Assalamualaikum

In this video we'll do a numerical on efficiency of lap joint in bolted connection.

For efficiency we'll calculate 4 values-

1. Design Strength Of Plate Due To Rupture Of Critical Section(Tdn)

2. Design Strength Of Bolts In Shear(Vdsb)

3. Design Strength Of Bolts In Bearing(Vdpb)

4. Design Strength Of Solid Plate(Tdg)

If you haven't watched my previous video on how to find efficiency of a bolted connection then you can watch here by the link given below👇👇👇

Hope you all like👍 this video & must comment👇👇👇 below & don't forget to subscribe👆 to our channel for more updates.

Show your love💚
Keep supporting🥀💛
Рекомендации по теме
Комментарии
Автор

Thanks a lot brother, u need to be steel faculty in my clg. 👍🏻

mohammadafzalmohiuddin
Автор

Bro, please solve this question - Design the welded connection to connect two plates of width 200mm and thickness 10mm for 100 percent efficiency.

somritolongmailai
Автор

Jab numbers of bolt 2
To critical condition main kitna bolt se multiply karenge

vi_mlesh
Автор

Sir, Strength of solid plate per pitch length ka formula kaise hoga ?

siram
Автор

Bhai ye vnsb ka aapne kese kiya hai mera calculation btao to vnsb=400/√3(1xo.78 ^/4x(20)2+o
565.9 ye kese aya btao.. hmara to alag aara 🤔

saadtipuhussain
Автор

🙏🙏🙏🙏 thanks you soooo nhi much brother

KaranSingh-fowg
Автор

Bhai...shanti wale jagah se video banao ...pls

vr
Автор

Agar do alag alag thickness ki plate ho

funkyboy
Автор

Strength of solid plate per pitch used karte hai ?

siram
Автор

Sir, kabhi kabhi An=(p-do)t hota hai.. please fark bata dijiye bahut confused hai

siram
Автор

Bhai Kisi me An ki value (p-ndn)t liya hai aur kisi me An ki value. (b-ndn)t liya hai, dono ka kaha kaha par use hota hai.
Please reply

manishkumar-pvrl
Автор

Bhai Fub ka value kaise 400 aaya kuch samja nahi please clear bata dijiye..?

siram