How To Terminate Cat6A Cable End

preview_player
Показать описание
Apologies re the sound distortion in the second half, I managed to butcher then ..mostly salvage it! Damned GoPro.

How to terminate Cat6A cables.

Smash a Subscribe for more How To Electrical videos!
Рекомендации по теме
Комментарии
Автор

Very well done and easy to follow! Thank you!

Mjmccutcheon
Автор

Ideally, use patch panels and factory made cables. I cut DIY cables in half and chuck em in the bin. Not worth the hassle even if you get paid by the hour. Problem with DIY is most testing is with a $15 ebay special or no testing at all. Use velcro to secure network cabling not zip ties. Leave a service loop of about 1-2m in the roof/wall/hidden on all network runs. Other than that, nice video. Wouldn't bother with Cat6a patch leads just yet but if you are running cable through buildings, definitely run Cat6a.

droy
Автор

Some useful tips and tricks in there, thanks!
However, I'd argue that it is a mistake to not leave the shielding foil and braid, until you've attached the connector and crimped, then only cut off what comes out backwards from connector. With the metal side of the foil outwards and the braid you will ensure that the cable shielding and not only the ground wire is connected to the shielding of the RJ45 connector. (For best possible signal integrity I think you'd want a low impedance path to ground for any common mode noise along the whole cable, for all twisted pairs.)

Boffet
Автор

Enjoy all your videos Dave. Keep it up. Thanks 👍.

josephsoloai
Автор

Cable manufacturers are removing the stripe from the white cables. It's not a fault. Wires without a stripe can perform slightly better in some situations.

abhibeckert
Автор

Gday dave ! Hope you've been well. U uploading anymore videos soon?? Take care mate.

liamjohnson
Автор

helpful trick is to untwist with a screwdriver from the base it helps straighten the wires as it untwists them

MarcusMussawar
Автор

Nicely done Dave Thank you appreciated

saraabodian
Автор

Thanks mate, Do I hear a wee bit of Scottish in your voice 🏴󠁧󠁢󠁳󠁣󠁴󠁿👍

championkhamis
Автор

strange... ASNZ standards say use 568A only they dont recognise B

Ressy
Автор

That is a cat7 cable, but otherwise is a correct way to terminate 6a.

cheerbeerification