Extending CAT 6 Cables

preview_player
Показать описание
Have you ever needed to extend or repair a CAT 6 Data Cable? This handy little junction box from TUK is a great solution. It features punch-down connections and click-in cable strain relief.

Click the links below for more info and let us know what you think in the comments.

==AD=============================
Featured Products:

TUK Junction Box

TUK Cyclops Stripping Tool

TUK Kwik Strip Network Cable Stripper

TUK Insertion Tool
=================================

🔦 More electrical short videos from eFIXX
==================================
⚡️ Take a deep dive into the latest electrical products, applications and technology
=========================================
#efixx #shorts #electrical
Рекомендации по теме
Комментарии
Автор

Generally speaking you only extended as a last resort.
Always to and run a new length if possible.

johnharrison
Автор

Note on the product page it says “Full compliant with Category 6 standard requirements for a consolidation point.” so it’s for use as a consolidation point. I presume if you use it as intended then you won’t have any problems (which several commenters don’t seem to have twigged) but keep it 15metres or so from the relevant end to avoid problems with signal reflections as per the standard (and make sure you read the standards referenced and required by 7671 if you haven’t already)

lkchild
Автор

This fails on return loss but will still function with little issues, but in regards to certifying a network using these not a hope.

eamonnblake
Автор

I have done this some times in old buildings where the cables have been accidentaly cut somewhere in the middle. It will work fine for the most part, but with so many terminated parts on a cable, there is a chance the return loss will be higher then what the fluke tester allows as a pass

RandomNorwegianGuy.
Автор

Never seen these before. We would usually use a keystone and male end, typically within the rack. I suppose this could work if you have to splice a damaged cable far from the termination points.

psychlology
Автор

Nice unshielded CAT6.. these are the best

lexeindhoven
Автор

Another satisfying video. Thanks, from Central WA, USA.

ryah
Автор

Krone rocks... it's rare to find it in the USA but I love it when I get to work with it, it's so much more refined than 110 punch-downs.

aaron
Автор

Gosto muito das ferramentas que utiliza nas atividades ❤

Ana_ofzz
Автор

It’s really important to know that no one is hiring an electrician to install network cabling and do joints or terminations if they care about it being 100% compliant and the best possible installation you were generally higher someone who specialises that however this is good enough for the average homeowner who just wants a couple of runs installed

UKsystems
Автор

Its like your very own man in the middle box ❤

godlugner
Автор

I mean, you did it. But it is stil haram

adjithwk
Автор

If this is stating behind wall you should always do a fresh run with a fresh solid core wire from scratch for the full run. old wire fails in time either way so your just giving your self a headache here as you will need to reaccess this in a few years either way. If it's coming to the front just use a normal jack.

julabask
Автор

Don't forget to follow the A/B scheme lest you end with a crossover cable!

rocketgirl
Автор

Well done for keeping the twists, but cutting the conductors to different lengths makes it no longer within cat6 specification.

markdee
Автор

Really decently needful items tool for your works smoothly

vincentjoseph
Автор

Whats this called a chrone switch..the box

stephenflanagan
Автор

I would just use a coupler what am I missing here?

Sharpboat
Автор

Me building a redstone machine in Minecraft:

evanwines
Автор

Question: I have a black and red wire in my cable, what color wires would they go with?

Gino-veob