How to Connect two Fire Alarm Systems Together as One

preview_player
Показать описание

Рекомендации по теме
Комментарии
Автор

WHAT A COINCIDENCE!! I was wondering how to connect a two fire alarm systems together! Perfect timing Nic! Good job!

_lifts
Автор

You do the best "How To's" Seriously!

GrifsProductions
Автор

Always gently wondered this in the back of my mind. Thank you for sharing with us! :D

ShayBlez
Автор

Back in elementary (and middle) school we had two buildings (one with preschool, kindergarten, cafeteria, and gym, and a second with 1st-8th grade) half the first building had an old Edwards system, the second half had an addressable firelite system. The second building had an addressable notifier system. They were linked together in a loop

leoschneider
Автор

I feel like this would be a non-conventional way to upgrade an existing conventional system with an addressable system without having to rip the old system out. Oooor, putting a new system into a maxed out conventional system when an additional building is annexed into the main building. Food for thought I guess!

AT_Videography
Автор

Pretty interesting! My school has 3 wings + portables and that is not counting the fact that our school is being remodeled to a 2 story config. Currently, all our wings have diff pull stations / alarms. Not sure about panels but I've seen 2 between the 2 offices.

jackdevvs
Автор

Hey everyone, would it be funny if Nic had his german shepherd pull a pull station for a video? That would be funny.

All_ConsumingBandu
Автор

I've seen a panel link with a vintage AC panel and a communicator panel that had a retrofitted relay that was wired in series with the bell circuit on the old panel.

Blixt
Автор

I was just about to ask you to do a video like this... i have a ms5ud, and i wanna get a notifier nfw 100x and have them linked together... so, thanks for making this video it will be helpful in the future

That__dude
Автор

First🎉🎉 can’t wait to finish the video thanks for all the vids nic

Charlieyt-be
Автор

Nic, can you do a video about how to connect security alarm to fire alarm?

nicholasd
Автор

You can also disable the other panel zone, and then reset the system :)

geko
Автор

ESTis trash notifier is pretty good. Simplex is pretty good in someways. firelite is all right.

GentexGuy
Автор

it would be cool if there was a tracking alarm feature, where similar to a tracking supervisory, it is only in alarm while a condition is met, otherwise it's normal.

wibwabz
Автор

this setup still can work...however both panels will also need their companion panels annunciators at both locations

ex:

Location A: Main Panel A + Annunciator B
Location B: Main Panel B + Annunciator A

or you can also do:
Common Location: Annunciator A + Annunciator B

Point is, you need to have a common point of physical control of both systems regardless of where the CPUs are located

the_drummajor
Автор

i am gonna imagine you could not hear for a bit after that holy crap

crazyboy
Автор

Would a mini monitor module work for the addressable to conventional panels??

dantestoner
Автор

Can you make a tutorial on how to make one panel trip the other into supervisory?

bikeblvd
Автор

the issue with resseting the both systems if i had this as an connected system from my room to my outdoor building i would disable the zone on one panel so when i reset one the other system dosent need to go into alarm again. and in the end i can reset both and when both are resetted just enable the zone again.

alfonsgamingtornadosirenfan
Автор

1 HOUR AGO, AND THIS MANY COMMENTS?? Wow, Nic is Extremely famous

ZoltanFranko-Doro