Proper Way To Connect A Earth Rod

preview_player
Показать описание
Domestic earthing👇👇

Live a LIKE, COMMENT & SHARE this video.

PLEASE GO AND SUBSCRIBE TO MY CHANNEL:

FOR MORE CONTENT.

LIKE ME ON

#earthing #electricalhouseearthing
Рекомендации по теме
Комментарии
Автор

Good job. Here in US the rules specify to have top of rod 2feet under the ground, so once installed, only the wire sticks out...

VDJ
Автор

Why push only the electrode into the ground without conducting materials like salt and charcoal?

chukwumachristian
Автор

Do the earth rod makes the grounds stronger or the light?? What does it do

leonphinn
Автор

Thanks for the video, what was the area mm2 of the grounding wire that you attached to the earth rod

emmanuelsalihu
Автор

The code specifies that you use a 8 foot ground rod of 5/8 inch solid copper or brass.

danclayberger
Автор

Is the ground rod not supposed to be covered with earth?

safetyalways
Автор

Nicely done. Only thing is code states complete rod must be in contact with earth. There is about a half foot of rod sticking out of yours. Any special reason why you don't bury it completely?

zombietxff
Автор

hi, can this be done from a power conditioner ground binding post going to an external ground rod? thanks for sharing this!

Libra
Автор

And what prevents humidity entering the wall through that hole?

gajnjaca
Автор

Hello, please can this be done in front of a building?

EmmanuelQuainoo-yy
Автор

Can anyone get shock for earthing wire or rod for touching it or something?

subhraprakashsantra
Автор

Mine is like that, I want to pour concrete to make a driveway. Should I pour over the rod and wires or should I make a space with no concrete for it ? Thanks

aramndoolvera
Автор

Can I run the wire that attached to the government pole to my house under the ground? I just don't like to see when it run in the air to the house

DeLifeOfaNanna-wpyb
Автор

Hi,
I am planning to this GI pipe earthing near my plastic water tank,
Will it be safe for us in future?
Please reply

ajaysharma
Автор

Please, why no salt, water and coal?

elohorolokpa
Автор

Dont hit copper bonded rod directly to soil. Dig the hole first. Copper plating will scratch

prabhathm
Автор

I don't like to see earth installation where it is dug deep into the ground

xlgoldfish
Автор

I though bare wire is out of code now and insolated wire should be used

sophiadunbarjames
Автор

is that rod even long enough to be grounded? thought they supposed to be 8ft

mlandis
Автор

You should have digged the ground 2 to 4 feet

chidaluprecious