2 stage Carrier package unit not cooling. call back?

preview_player
Показать описание
no Cooling Service Call. this unit was found with a failed condenser motor and a failing blower motor a few months ago. both motors and 2 contactors were replaced along with a low pressure switch, and the coils were cleaned at that time. today, I find major restrictions in both refrigerant circuits, contactors chattering, and one failed. small leak from the cormax on stage 2, but once recovered and weighed, I don't believe there are any other refrigerant leaks. filter driers replaced, and the orifice metering devices do not seem to be restricted at this time.
Рекомендации по теме
Комментарии
Автор

Well Steve you definitely had to have your thinking cap on with
That unit .problem after problem.
And the heat does not help ...
Looks like your getting there now 👍👍👍👍👍👍👍

johnwaby
Автор

I like the metal refrigeration caps with copper a gasket better than a swivel T, fewer places to leak.

HVACR
Автор

Great recovery on this one, if it’s 3*or 4* diff across dryer’s I call them toast . Gotta say all that chatter for the LPS is suspect as well .
Guess you were right in replacing it all . Thanks for the editing, posts, nd content . Much appreciated.

jamesortolano
Автор

That was odd...i would've also expected the pistons to be plugged as well. That contactor sounded like a machine gun 😂. Another great video Steve-o....thanks for sharing

jasonjohnsonHVAC
Автор

Great job Steve. You need to be careful on those roofs take lots of breaks. Be safe.

helmsajr
Автор

Great work 👍 I believe we got your full video

stephenbullock-ynvh
Автор

once you touch a system you seem to own it and always a call back. I just had one the freezer failed our tech went out and capillary blocked so they replaced it then 3 days later it fall over again.... I was sent to find coil iced up and unable to put it into defrost due to sensor faulty. Replaced and working fine now. I let the office deal with the aftermath. 🤣🤣🤣

jochemsluis
Автор

Another great video, can you get to a bandsaw to cut those old filter driers open?

Sure would be interesting to see what’s on the inlet side of the media block.

rcf
Автор

Still watching, but what’s the jumper on the board for?

HVACGUY
Автор

Good vid Steve-o ... Be like me and drink plenty of "' Fluids'' Thx

Eddy
Автор

all the units are getting time delays.

MariosACandRefrigeration
Автор

Dude, you can’t check the amp draw on the fan motor with the door open! That is not a realistic amp draw