This video shows how to replace the Sentinel HD35P fan motor.

Step 1: Loosen the 8 screws on the side cover of the gravity drainage interface and remove the cover.

Step 2: Remove the 8 screws on the side cover of the control panel and take off the cover. Disconnect the cable of the control panel.

Step 3: Remove the 4 screws from the top cover and remove the cover.

Step 4: Remove the two screws on the air outlet plate and disconnect the cable of the data connector.

Step 5: Remove the fan ground wire, remove the fan capacitor wiring, and remove the fan wiring on the motherboard.

Step 6: Remove the four screws on the fan socket and take out the fan.

Step 7: Reinstall the fan and secure the four screws to the fan base; reinsert the fan wiring and secure the ground wire.

Step 8: Install the air outlet plate data port wiring and install the air outlet plate.

Step 9: Install the top cover. Reconnect the panel wiring and install the panel side cover. Install the panel on the gravity drainage side.