Sentinel HS35 Dehumidifier Replace the Fan Capacitor

preview_player
Показать описание
This video shows how to replace the fan capacitor for Sentinel HS35.

Step 1.Remove the 8 screws on the side panel of the drain side to open the panel.

Step 2.Find the fan capacitor and unplug the two wires on the fan capacitor.

Step 3. Remove the screws holding the fan capacitor and take out the fan capacitor.

Step 4. Replace the fan capacitor with a new one and reinstall it.

Step 5. Connect back the plug wires and clamp them.

Step 6. Install the side panel back.