Chiller working cycle

preview_player
Показать описание
इस वीडियो में हमने chiller working cycle के बारे में बताया है।
Note ✍️. Compresser के बाद Condenser मैं refrigerant की Position high pressure और low temperature होती है By mistake मैंने high temperature बोल दिया था


📷🤫🙊 Our other videos
1. HVAC plant knowledge
2. Chiller working cycle
3. How to start chillar
4. Your chiller all part detail
5. How to set chiller Load for more efficiency
6. Gpm calculation of chiller
7. Chiller Load calculation

#MEPINDIA #chillarcycle #refrigeration
Рекомендации по теме
Комментарии
Автор

Bhai tumhare is drawing ne mujhe job dila di bahot bahot shukriya mumbai

samskazmi
Автор

Bahut aacha samjatahu bhai tum Dil se Dana wad

saifkhan-dtpc
Автор

Very good explain bhai chiller & AHU cycle

sureshingle
Автор

Cooling tower ne jb heat exchanger kr li hai compressor se to dry filter ke pass HT kese ho sakta hai ?

sanyamsharma
Автор

High pressure mediam temple ho jata hai condenser sei out ho ta hai toh

AdilKhan-juqu
Автор

Pehly condenser liquid form ma karay ga phir evaporator vapour ma

BilalAwan-qsjo
Автор

Bhai oil seprater(Dry filter) condenser se pehlay ay ga kyun k ye gas main se moisture ko khtm krta ha condenser k bad ni ho skta kyun k tb to hoti e sari liqiued fom to phir konsi moisture khtm krni ha😅.

asadkhan
Автор

Same on chiller evaporating coil, when temperature exchanged by ahu how can temperature still low at 1st point it should be HT and LP.. !

sanyamsharma
Автор

Which type off expansion valve in water cool chiller in yourk

diclva
Автор

Condenser se refrigerant nikalne ke baad temprature low ho jata h but pressure same rahta hai

alexfiroz
Автор

Brother, How is it possible for refrigerant to be at High Temperature after leaving from condenser? If it happens then Chiller is not working properly, Refrigerant must be at Low Temperature after leaving from condenser because it exchanges heat with the water coming from cooling tower and also expansion valve reduces pressure of refrigerant not the temperature.

azharhashmi
Автор

Sir ap na absorber ka bari ma bataya he nhe

qayoombaloch
Автор

Na heat axchanger ka bari ma bhe nhe bataya

qayoombaloch
Автор

Sir, condenser pump galat position par laga rakha hai
Because, cooling tower terrace par laga hota hai water khud niche ata hai, condenser se water cooling tower me pahuchane ke liye condenser pump ka use Kiya jata hai.

krishnasom
Автор

Brother your explanation is great but I don't think this BGM was needed for this video😌

rameshsj
Автор

Aur chiller misson diagram dalke explain please