Working Principle of Chiller Plant | Animation | English

preview_player
Показать описание
In this video we have explained about the water cooled chiller plant basic working principle.
We have created this video with animation So you can understand easily.
Please Subscribe and Support our channel.
Like and Share the video.
Ask if you have any doubt in the comments section.
Рекомендации по теме
Комментарии
Автор

AMAZING!! thank you for the quick informative video! much appreciated

ryanreinoso
Автор

Hii brother
Can make one video on district chiller.

Your videos are very useful and easy to understand in a simple way 🙂

Thank-you

MVBSHADABARSHAD
Автор

Thanks good video nice PervaizIqbal from Karachi Pakistan

pervaiziqbal-jwis
Автор

This very good video havc system traubleshooting good

balbahadur
Автор

Like the animation except the mistake of the flow. The hot water exiting the condenser should fall from the top pipe down not the bottom pipe up. Other than that good and informative

firstnamelastname
Автор

Do like to share this informative vide please.

zabidi
Автор

Can you show only pipe line diagram without chiller? 😊

msconstruction
Автор

Which part would output/emit hot air (due to the process, if there is) into the environment? Is it the cooling tower? and would such cooling tower be mouted on top of the building roof?

susancoalfield
Автор

Sir..just asking..I stop the AHU sistem..do i need to stop the chiller water pump?

bedjack
Автор

1:45 flow through the "Condenser Water Pump" seems backwards.

fredsalter
Автор

Brother which software used in this video image. Please tell me ❤

samhaazratechnicalsupport
Автор

Job v dedo yar 😢knowledge ke sath sath😂😂😂

rehanff_
Автор

How to find
Efficiency
Approx
And delta T of cooling tower and chiller???

faisal-hwcm
Автор

why does this system need a cooling tower if it already has a chiller. Seems that the cooling tower only contributes to cooling the water by 5 degrees, a marginal contribution.

zepedaherbey
Автор

I Think direction flow for suction and discharge is wrong. thanks

definal
Автор

U didn't mention what goes on inside the chiller between the evaporator and condenser

hfcarwash
Автор

R134a refrigerant chiller plant section pressure???

aminokz
Автор

How does water go to cooling tower from condenser witout pump

mohdaltaf
Автор

The pump is on the wrong side because the suction of the pump is horizotal and the pump is discharge pump is on top.

aekkupbori
Автор

Chillers with AHU doesn't make sense to me! Why not just use AC and put the evaporator in the AHU?
I've seen some buildings that don't have the AHU but the chiller's cold water goes into the building and special radiators with blowers cool down the interior.

ghenkhoash