How to pass strong column weak beam check in ETABS Tutorial

preview_player
Показать описание
How to pass strong column weak beam check in ETABS
Special moment resisting frame design
SMRF design
This videos shows the concept of strong column and weak beam.
ETABS CERTIFIED PROFESSIONAL COURSE FROM BASICS TO ADVANCED LEVEL
aci strong column weak beam
concept of strong column weak beam
explain strong column weak beam concept
explain weak beam strong column design philosophy
how to check beam column capacity ratio in etabs
how to check column reinforcement in etabs
how to check deflection of beam in etabs
how to check strong column weak beam
how to check strong column weak beam in etabs
how to strengthen steel columns
konsep strong column weak beam
seismic performance of weak-column strong-beam steel moment resisting frames
strong beam weak column failure
strong column and weak beam concept
strong column weak beam
strong column weak beam aci
strong column weak beam calculation
strong column weak beam check
strong column weak beam concept
strong column weak beam design
strong column weak beam example
special moment resisting frame
special moment resisting frame concrete
special moment resisting frame definition
special moment resisting frame detailing
Strong column weak beam is very important concept in structural analysis and design. It's desirable to have failure in beam but not in column as it will cause collapse of structural system. You can check this by calculating stiffness of column and beam and taking ratio of that.

#engineering #etabs #design
Рекомендации по теме
Комментарии
Автор

Watch, "How to pass strong column weak beam check in ETABS Tutorial"

EngineeringLearningPlatform
Автор

strong column weak beam check was an awaited tutorial, thanks

zahidairfan
Автор

thanks for sharing this video, I would like to ask, is it needed to use modifier 0.25 for slab in slab beam system, I checked ACI-318 - 19 for that and its written that its necessary for flat plates and flat slab

laythhasan
Автор

Does ETABS check the shear strength of Beam-Column joint as per IS:13920-2016 cl.9 over and above Strong column-Weak beam check? How can I verify the check?

dilipngangom
Автор

AOA brother. Udemy par ju course ap me upload kia hai us mai detailing ka portion cover kia hai ap ne? I mean complete working drawings ju ham banate hein submission ke leye.

Engrwaleed
Автор

how can i check strong column weak beam if I have a intermediate sway? as We know, Etabs just calculates strong column weak beam for special moment frames.

andresdavidtorrescarranza
Автор

Can you please share any technical doc that how etabs calculates it.

zahoorahmadnisar
Автор

are the wall loads include in mass source ??

adrianuslahiwu
Автор

can you explain the color of column it displays as red pink and sometimes as black

rcbsht
Автор

its nice..what about the size of 24" x 24" by increasing column will it feasible to adopt though the member size passed???

gowthamiv
Автор

What does N/A mean in c/b capacity ratio