Technician Hacks: Removing Air Bubbles from Fluid Lines

preview_player
Показать описание
DoveLewis Technician Trainer Jessica Waters-Miller, CVT, demonstrates a technician hack for removing air bubbles from a fluid line.

#veterinary #vettech #airbubbles
- - - - - - - - - - - - - - - - - - -
- - - - - - - - - -

Рекомендации по теме
Комментарии
Автор

Stop fluid flow, close off or pinch off line below where bubbles are located so that bubbles are between pinch and fluid bag. Insert large sterile syringe (10mL or larger) with needle into extension port (if there is one attached to main line) or screw on if ports are leur lock safety ports, and draw back until all bubbles have been removed. Then take syringe and insert into port on fluid bag to re-introduce fluid to bag. Re-open fluid line.

Melaboo
Автор

Hold the line taught just above the bubbles and flick the line like a guitar string while elevating the line, the bubbles will flow in reverse of gravity (climb the elevation you've made) with each flick.

With this you can work the bubbles all the way to a port or to the end of the line for a quick 0.1ml purge prime or extraction with port access for reinsertion into the bag.

KingGumboot
Автор

The first part is the part I am looking for and you just simply say obviously we can do this. Thanks really helpful

kylebushnell
Автор

Clamp the t-set at the patient or close the roller-clamp on the line first. If this is not done, the patient may bleed back up the line. Closing the line closer to the patient and then "stripping the line" upwards to move the air back into the bag, will collapse the line between these two clamps. Open the clamp closet to the bag first, then open the one closest to the patient.

shalomjade
Автор

great tip ! thanks for AKING THE TIME TO TAPE

songlyon
Автор

I do home IVs with my PICC line due to HG. I get super tiny bubbles that always stress me out and I struggle often with priming the line effectively. I'm no medical professional but I'll try these hacks I'm about to do a treatment

mads
Автор

Brilliant simple hack, trust a tech to find the best and smartest thing to do

deedopix
Автор

Thank you. could you post more videos on how troubleshoot IV when not dripping?

snakeeater
Автор

woah I‘m gonna try the one with the pen. ty 🙏😊

Dev_
Автор

18 Guage needle into the IV line port (assuming you have an extension line added to your primary IV line, this would allow you to have to access ports if need be depending on where your bubbles are) open iv pump clamp and let fluid run till bubbles exit via 18 Guage needle of course some fluid will run so best used for non CRI fluids. Hope that makes sense.

mentallycrafted
Автор

I would just attach a 10cc ns syringe, clamp down flow and flush the bubbles up to bag reopen . Hundred ways. You could attach a syringe downstream and suck the air into it as well.

ryhol
Автор

How about the roller valve? There's none in the clip, but mine has.

muangfaa
Автор

Nice.. but do we need to disconnect the iv line first?
Or is there any need to stop the flow before doing these?

priyakale
Автор

Whats the effect if ever air bubbles enter your bloodstream

delbovevencia
Автор

I tried the rolling method before and it didn't work. I like the first method

tiarob
Автор

I do it with the pen but when I removed the pen the bubbles still there