How to communicate siemens S7 300 PLC with Danfoss VFD via profibus using TIA Portal ? #43

preview_player
Показать описание
Download link for GSD file Danfoss and TIA Portal v 13 Project

How to communicate siemens S7 300 PLC with Micromaster 440 VFD via profibus using Simatic Manager ?

Please Subscribe to Easy PLC Tutorials for more Videos and Tutorials
Siemens S7300 PLC communication with Danfoss VFD Automation Drive using Profibus
How to communicate siemens S7 300 PLC with Danfoss VFD via profibus using TIA Portal ?
Рекомендации по теме
Комментарии
Автор

no joke, this channel is seriously good. Thanks

Jarito
Автор

I have to watch again. So much value in here. Thanks for your time in putting this together

judetochukwuogbozor
Автор

Thank you very much I search a lot in web but your video explane it easy and hope to keep going bro😊

medosust
Автор

Excellent video, thank you for making it look so easy. 👍🏻

arsalannisar
Автор

I'm using an s7 1200 and a fc280 but nothing looks like the interface you're using, I also don't understand the various codes or why the memory blocks get used, any video where I can go to explain this to me ?

JustFrana
Автор

This video is very helpful for the beginning. Thanks

MuhammadYaseen-ogls
Автор

You really helpful for me.
Thank you sir.

shahbazarain
Автор

thank you for the video . could you make a video about how we can read the manual of vfd and the main informations that we can have from it .

Bigmallone
Автор

If there was multiple drives, then how can I move control and status word ? Please make a video on multiple drive.



In program you have not use node address, how CPU will understand that I want to start or stop that particular drive.

TechnicalManas
Автор

wow .. it helps a lot for beginners lke me

nikkorogelio
Автор

Hey, do you have the list of the parameters to check into the Drive. I have problems programming fc106 with profibus

dennismuralles
Автор

I HAVE ISSUE: in video
(FC): out: controlword and referenceword.
BUT
(MAIN): out: statusword and referenceword. i dont understand here.

nguyenlethanhtrung
Автор

Hi

How did you get the code you are inputting for forwardrun, reverserun, stop, and reset alarms mode in the program you wrote. Like these codes: #16#0480, #16#047C etc

amaohabeeb
Автор

what is gsd file ??? that is used for danfoss vfd???

alrazi
Автор

Hi thank you for this vidéo but juste question l not understand the differente code for controle VLT can you write it here ?? Thanks

hakimchabane
Автор

Please can I also understand what determines the 8 points (on and off switch) position on the communication card?

judetochukwuogbozor
Автор

hello dear, appreciated your work. Just a request for you. Can you please provide a soft copy in which you listed all the necessary parameters required to interface any Drive (Danfoss, Siemens, Parker, Mitsubishi, etc) with the PLC? Also, it will be a plus if you add a video in which you can provide a detailed comparison b/w Simatic manager and TIA portal so the user of Simatic manager can easily switch b/w these two applications

atifahmed
Автор

Hello,
Good Video.
Which profile you selected in drive?
FC profile or Profidrive?
Please send same for profinet
Thanks

stolzsolarandautomationtec
Автор

What are the model name on the Danfoss vfd

kennethkristensen
Автор

You use "rising edge command" in this program but don't use in g120x program, any reason?

muhammadshehbaz