How to calculate the load in a column? | Approximate Method of load calculation | Civil Tutor

preview_player
Показать описание
Download our android app for job oriented courses👇

In this lecture I have explained briefly how to calculate the axial load in an column

PDF + Excel sheet 👇

Compiled PDFs 👇

Must-have books for civil engineers 👇🏽

The A to Z of Practical Building Construction and Its Management

Building Planning and Drawing

Illustrated Design of Reinforced Concrete Buildings ( Design of G+3 Storeyed Buildings + Earthquake Analysis & Design)

Advanced Reinforced Concrete Design

Limit State Design of Steel Structures

Estimating and Costing in Civil Engineering (Theory and Practice)

The mic I use👇🏽

#civiltutor #rccdesign #columndesign
Рекомендации по теме
Комментарии
Автор

Really applaudable effort from you for new civil engineers like us
Greetings 🙏🙏

shivamtripathi
Автор

Really I'm 1st time appreciating for structure even not in clg. Lovely 100% satisfied

RahulKumar-wchh
Автор

Your efforts are Really appritiated. Thank you for a very easy and straight explaination !

accessdenied
Автор

You are very hepful to many. Be Blessed

JuliusMlengeswa
Автор

The excellent clear calculation any student can easily learn 👌 try to give more knowledge of civil engg, , thank you 👍

ganpatraobhosale
Автор

I do appreciate your sharing of this precious lecture..thanks

babikermohamed
Автор

Thank you very much for your helpful information,

Is there an earthquake load in the calculations you made in this video?

Thanks

Hakan

muranoaydnlatma
Автор

excellent column 6 specific area load calculation but as i understand this load on column 6 from roof, then 1st floor then is for specific area surrounding the Column 6 #

ziauddin
Автор

Helpful and handy,

Nice video thanks

bari
Автор

Self weight of plinth beam =.3 *.6*25 *9 meter, you took it as. 3*.3*25*9

ananthuaravind
Автор

Thank you for this video this is nice and detailed.

alvinmuridil
Автор

Can you do the column moment calculation

jotdown
Автор

Sir I think interior column the load should be maximum, for side column the load lesser than interior column and for corner column the load minimum as compared to interior column.

azaroddintamboli
Автор

Where did u put the self weight of the GROUND FLOOR?

odyromero
Автор

Why self weight of column was not factored? (Like 13.11 x 1.5)

prasanna.k
Автор

I got confused: how do we get wall load(primary) in load transferring from roof to 1st floor? There is only parapet wall as a boundary, isn’t it? Could you explain this?

darshanshrestha
Автор

Helo sir... Total load on C6 = 915KN and SBC of soil = 150KN/m2... Is it safe?

sathishvijay
Автор

What about software sir is acces free or not or without software how we can learn

darshandattu
Автор

About all total Factored load, how to know that must be Times to 1.5?

卡卡弒神
Автор

Thank you Sir for this video of yours. But i will like to know, why is there no slab load and wall load transfered from the ground floor to the footing?

Nyaburunga