How to set up the ABB Electronic Circuit Breaker - TMAX

preview_player
Показать описание
How to set up the ABB TMAX Electronic Circuit Breaker presented by Katie Rydzewski for Galco TV.

Connect with us!

Don't forget to like and comment on this video, and subscribe to our channel!

With respect to the usage, installation or assembly of any products described in this video, Galco Industrial Electronics, Inc., a Michigan corporation, encourages you to follow the requirements and/or guidelines of: i) the Occupational Safety and Health Act of 1970, Public Law 91-596, as amended, and all laws, rules and regulations implemented in relation thereto; ii) the National Electric Code®; and iii) NFPA 70E®. Any installation, assembly or work described in this video should be performed by a qualified licensed electrician.

LEGAL DISCLAIMER:
While we have made every attempt to ensure that the information provided is accurate and has been obtained from reliable sources, Galco is not responsible for any errors or omissions, or for the results obtained from the use of this information. All information is provided "as is", with no guarantee of completeness, accuracy, timeliness or of the results obtained from the use of this information, and without warranty of any kind, express or implied, including, but not limited to warrantees of performance, merchantability and fitness for a particular purpose. At all times you should defer to the instructions and safety guidelines issued by the manufacturer. In no event will Galco, its agents or employees thereof be liable to you or anyone else for any decision made or action taken in reliance on the information provided to you or for any consequential, special or similar damages, even if advised of the possibility of such damages.
Рекомендации по теме
Комментарии
Автор

The dip switches on the S/I setting were skipped over in the video, I don't believe they stack like the L setting does?

gamestopape
Автор

The ABB TMAX has an electric arc interruption system used on the Tmax circuit-breakers allows the short-circuit currents of very high value to be interrupted extremely rapidly. The considerable opening speed of the contacts, the dynamic blasting action carried out by the magnetic field and the structure of the arcing chamber contribute to extinguishing the arc in the shortest possible time, notably limiting the value of the specific let-through energy and the current peak.

GalcoIndustrial
Автор

Hi I have a TMAX T3C 250 that needs to be replaced, I checked there is no old model, what is the replacement for it because I checked the old model and there is no one available

jojoprieto
Автор

Is the 50/100% neutral setting a % of the L dip switch setting or the breaker maximum or 50/100% of something else?

danpallant
Автор

Thanks for sharing i have same abb breaker its working normally but after shutdown its not working what is the issue ???

mehtabhashmi
Автор

@GALCOTV Do we need to set the MCCB to TEST position before changing the DIP Switch position and setting ?

RheyEarth
Автор

PDF of this circuit and all information PLZ

ammarbasrah
Автор

Sir I have a 630 Amp ABB sace Tmax mccb, it's getting trip during starting of motor, as motor is connected to fan load it take 936amps current for 50 seconds and then back to nominal current, Plz help for trip time characteristics

manojKumar-ykez
Автор

HOLA PODRIAN HACER UN VIDEO INSTRUCTIVO EN CASTELLANO PORFAVOR

neyster
Автор

What is the LUG TEMPERATURE RATINGS of IEC BREAKERS?

bobcocampo
Автор

I need to set up the ABB circuit breaker RC222 please

khalidkeetah
Автор

How about explaining the multipliers for the Long Time and the short time. You skipped over that bit. Thanks

nolanyoung
Автор

Sir I have a 630 Amp ABB sace Tmax mccb, it's getting trip during starting of motor, as motor is connected to fan load it take 936amps current for 50 seconds and then back to nominal current, Plz help for trip time characteristics