PH Meter calibration issues Part 1

preview_player
Показать описание
Trying to calibrate the meter with 6.86 buffer powder solution. But it keep shown error and unable to read any ph. Help help..
Рекомендации по теме
Комментарии
Автор

I sprayed the glass bulb with Isopropyl Alcohol (IPA) and soaked the end in hot tap water (as hot as your faucet has), blasted with IPA again, gently scrubbed the glass bulb with a boar's hair shaving brush and rinsed the tip and bulb in hot water. After I dried the tip off I soaked the end in distilled water and was able to calibrate the PH meter. Dried gunk gets built up on the glass bulb especially if the meter is used for measuring PH of hydroponic solutions which have dissolved salts, etc in the solution.

MrDabrudda
Автор

Same here, I’m only being offered a refund. I tried the take the battery out and it still doesn’t work. I even tried soaking it in distilled water and still no luck!

chiefr
Автор

Same pen same issues . Even with new batteries i think this pen is a peice of junk going off how many people have the same issue

wraith
Автор

Mine will only calibrate to 6.86 but when try to calibrate 4.0 it will display 6.86 again can’t get It to go on to the next cal ph4.0

starlyncabrera
Автор

I have the same problem here! anyone found out what's the issue? thanks.

ArashJooya
Автор

Im having issues with one that looks the same. Did you solve it? Manual says to soak the tip in the liquid for a few hours... trying that now.

PickledAndFermented
Автор

The same with mine and same pen too, Did you sort out? what should be done?

MaxSignsJames
Автор

Important!!! Or not but i just got a new one today and used purified drinking water (not sure if wrong) for the packets at 250ml and I would get the error when trying to calibrate the 4.01 ph one and wouldnt go away unless i removed the battery, but then I calibrated the other two packets with acurate reading and tested the 4.01 ph and it was at 3 ph so!!!! **I think if you try to calibrate without the correct ph lvl you might get the error code.

daviddelgado
Автор

Same Issue for me also...
Any solution or fix ?

arung
Автор

mine did same thing ...remove the battery to reset and then try it again...mine worked!

frankdesantis
Автор

The seller sent me the new unit after seen this video.

louis
Автор

Bisakah alat ini untuk ngukur ph urine

NovRizal-eu
Автор

Don't loose the press until the reading stopped blinking that's your wrong process

JordanUnidad
Автор

You have to invest in a decent pen and clean it with ipa regularly

monstermunch
Автор

Did you ever sort out the problem? or did you chuck it?

davewright
Автор

Your instruction videos was wonderful. NOTTT. WHY DID YOU WASTE YOUR TIME. Cat got your tongue?

rich
Автор

Hold calibration button for 5 full seconds.

catherinecarrigan
Автор

Here watching videos before I try this thing and this is what I'm seeing

jaoffgrid
Автор

exactly the same with mine and same pen too

davewright
Автор

This is so stupid i paid 15 bucks for a fking metter that i have to do all this bs to

mantyshub