How A Grease Trap Works

preview_player
Показать описание
Grease Trap
Рекомендации по теме
Комментарии
Автор

in theory the secondary water should be clear
in reality it almost always is as caked up as primary

ecsyntric
Автор

What app did you use to create these animation

asyzz
Автор

"Grease a trap works how" was the caption I got from the audio 😉🤷‍♂️

logannsif
Автор

Amazing integration I wonder if this can be implemented to produce naturally occurring gas for pilot lighting and monitored for efficiency. Home Improvement Master Class?

Jordan-kkrh
Автор

Here's the understanding/info sheet we have placed on our Grease Trap, you might want to copy, take care:
Grease Interceptor (aka Large Sized Grease Trap):

CS City Requirements1 - Avoids Keep 3 Mandated Maint Logs On Site, Of:
1. Monthly OUTSIDE Of Trap Inspection, Verifying If An Inside Clean Out Is Not Yet Needed.
Remove Cover, Looking For Telltale Thick F.O.G. Capping. Optional Method: Use Measuring Dipstick2.
2. Used Fryer Oil Disposal Method(Shows Was Not Dumped In Sewer Line Or On City Land).
See/Print City Man. p21 #3 “OUTSIDE Grease Trap/Interceptor & USED FRYER OIL Maintenance Log”.
3. Cleaning Out INSIDE Of Trap Is REQUIRED When 25% Of Tank Is Full Of F.O.G. & Solids3:
See/Print p20 #2 “INSIDE Grease Trap & Used Fryer Oil Maintenance Log” & P22 “Pump Procedure”.
TRAP: Required Due To Commercial Kitchens’ Inherent Use Of Sewer System Clogging Waxy: ‘F.O.G.”(Fats, Oils & Grease). Cools & Captures Incidental Floating F.O.G. & Falling Solid Waste(Food Particles Etc.). While Allowing Gray Water To Pass Thru.
Burden Must Be Minimized By Placing Sink Waste Into A Trash Can, Instead Of Down The Drain.
Effectiveness Diminishes @ 25+% Full(Typically Within 4 Months). Requiring Emptying-Cleaning Out.
This Building’s Plumbing Design, Only: Dishwasher, Tri-Sink, Large Deep Sink & Small Hand Wash Sink Drain Into This Trap-Inlet. The Outlet Water Travels Into The Bldg. Crawl Space Main Sewer Line.

BASIC TROUBLE SHOOTING CHART(Often Because It’s Time for A Trap Emptying Clean-Out):
SYMPTOM:
LIKELY CAUSE:
Grease Trap Top Cover Is Overflowing-Leaking.
The Internal Baffle OR Outlet Line From The Trap Is Obstructed.
Sinks Connected To Grease Trap Are Not Draining/Draining Slowly.
Obstructed/Partially Obstructed Trap: Inlet Line OR Outlet
Line-If Trap’s Cover Is Sealed Well Enough To Prevent Overflow.
Sinks & Toilets Are Not Draining.
Obstruction In Sewer Mainline.
Foul Odor-At Grease Trap.
Trap’s Cover/Seal Is Not Secured. Grease Is Old-Fermented.
Foul Odor-In Bldg/
Tank Clogged/Missing Internal Baffle/Part.
Grease Trap Is 25+% Full. Greasy Water Is Being Released.
1 Cup Bleach Down A Bar Sink Might Reduce Odor Temporarily.
1CS City F.O.G. Policies & Procedures Man.:

-
2Insert-Cap-Withdraw A Clear Dipstick Tube -
Fill Measurement Option, How To:

-
3Tank Inspection/Clean Out How To Overview:

JimTMcDaniels
Автор

Grounding by wire
Grounding by inductor

Ranges catered to
= Gauges and inductance and transmission before gunpowder creation.

Example - china blast mitigation for grease-trap gutter-oil country.

engchoontan