EXTERNAL EARTH FAULT LOOP IMPEDANCE - 3 PHASE SUPPLY - AM2S/E

preview_player
Показать описание
A practical example showing how to test the external earth fault loop impedance for a three-phase supply.

Essential learning for apprentice electricians taking AM2S or AM2E assessment.

Filmed with Eddie Clemmens of Pegasus Electrical during installation of a Schneider Acti 9 distribution board.

=================================
🕐 TIME STAMPS 🕕

================================

================================
========================================
eFIXX - EDDY CURRENT MERCH
========================================
🔴 eFIXX LIVE Join us for our youtube live stream twice a month - features product sneak peeks, challenges, giveaways and live electrical banter.
================================
================================
================================
================================
FOLLOW US on your favourite social networks for behind the scenes action, breaking news and competitions.
==================================
❌ This content on this channel is for electrical professionals.❌ ==================================
📹 Presented by
Gary Hayers - Editor eFIXX
===================================
#efixx #electricians
Рекомендации по теме
Комментарии
Автор

Them linked out earth blocks are a great idea to stop conductors being put back in and out, loose connections and the likes, nice video Gaz

ericthekingthekingtheking
Автор

Great video as usual. Obviously you are a knowledgeable guy. Your poor guy was bricking it.

paulspargo-thompson
Автор

Those MET bars are good. Any idea where i can get them from

wastemanboss
Автор

You can do a 2 lead hi test even though there are rcd’s in the board cause the board is off. This is the second video i’ve seen now you saying this now!

DLpTheRockStar
Автор

Where can you buy those MET blocks and all the labels???

onhno
Автор

Poor Ed looks like a real world spark who would have believed you if you told him it was Friday instead of Wednesday lol

robertwilliamson
Автор

Where did you get that earth bar from?

sam
Автор

So, what should be done if the reading is above 0.35 ohm? Should we contact the DNO? Would this make MCB's operating devices inoperable?

Wroe
Автор

Didn't expect to see Doncaster Cables - just down the road from me, they are!

SpartanMJO
Автор

THANK YOU FOR EXPLAINING, WILL HELP ME IN MY EXAM|.

aaplumbingheating
Автор

I never realised there were 3 different types of AM2. When I did mine back in day, it was just called AM2.
Could somebody tell me the difference between the other 2 different types of AM2?

TheManLab
Автор

I first time seeing that kind of test.

elangor
Автор

3 pole or 4 pole main switch at the DB on a 3 phase installation...worth a discussion in a future video?

TheYohtube
Автор

Any idea what brand that MET is? can't find it anywhere!!

KlusterYogo
Автор

What about PSSC ? Surely that’s going to be higher than PEFC 😮

abssend
Автор

AND L-N WHEN WE MUST USE.I HAVE A METREL 3125 MI BT, AND I AM CORIOUS.THANK YOU

ovidiuroman
Автор

Awesome video. Is this test usually done within the boundary of property or outside (on the councils side ), please clarify . Cheers

jonerasmus
Автор

Another wanting to know who make the MET's

luketaylor
Автор

Good job done there, but he did make a view mistakes, so give him a slap on the wrist 😂 ok he did sound a bit nervous .
Fantastic video as always Gaz 👍👍❤️

Dog-whisperer
Автор

That earth link bar really ought to be secured with security bits to discourage removal.

farmersteve