240V 30AMP outlet for my Mining Shed.

preview_player
Показать описание
My 240V metered L6-30R outlet for my miners. This is a fast over few of how its wired. I hope you all like the video.

Parts and tools used.

Рекомендации по теме
Комментарии
Автор

Currently trying to make this myself will see how it turns out

RabidMining
Автор

I'm gonna need 3 of those, thanks Space Goats lol

RedPandaMining
Автор

I figured you had a video if the wiring in the box…just had to look around more . Great stuff.

Giroux
Автор

What kind of cable is used inside the box? What does the other end of the cable look like? I assume it’s the same type of connector that you show at 10:29 and plugs into the wall where the electrician ran the 30amp circuit? Also what gauge wire did you use for the drox signal?

DB-bewy
Автор

Great meter, trying to build a shed like yours to run my future rigs

ghassounkilani
Автор

Great milestone more than 100 subsss yaayy. Keep it up 🙂

ghassounkilani
Автор

So how are you converting the 220 to 120 volt for GPU mining rigs? I need help ASAP...electrician is here

KeywordManagement
Автор

I like the camera idea for monitoring. I have been using smart plugs with voltage monitoring, but it's hard to find good ones for 220-240v. I will have to make a few of these soon !!!

cryptomininglifer
Автор

Space ghost I have a simlar issue in my server room. What plug do you use to convert the L6-30 to C14 to plug into the power supplies? Are you using a PDU? or break out cable?

StashMc
Автор

would have liked to have seen the other end of the locking plug cable... how to get multiple outlets for plugging those three rigs off one outlet? eli5, kinda.

deek
Автор

Whats the yellow and black wire on the green side are they spliced into each 120 wire for the 240 read? Got my box and stuff in need to wire it.

RabidMining
Автор

Those are sweet definatly need one lol

RabidMining
Автор

Is your outlet a "L6-30r" or a "L6-15r"

mrgoodlookin
Автор

Slick setup! Quick question on the wiring I couldn't quite make out from the video so please correct me where im wrong. For 220v both your black and white are hot (ie 110) green is ground. It appears you have just the white leg going through the transformer. Then you have a pigtail from both the hot legs (ie white=yellow pugtail and black = black pigtail) going into the voltage block on the meter, am I seeing that straight?

larryhotchkiss
Автор

Heck yeah! It is here. I need 4. One for each 30 Amp outlet :). Rock on man thanks for making this!

HashRaptor
Автор

Please get a set of isolated screwdriver and don´t work under voltage!
That´s definitely not save what you´re doing there.

darkness
Автор

So I found the box, and the meter on Amazon. What cabling do I use. Then how do I get it hooked up to the breaker?

erickwat
Автор

So there's a jumper from each hot terminal of the L6-30 to the green side of the meter, and one of the hots passes through the transformer ring? Is that correct?

MarkLenkner
Автор

I'm planning now to add these type of meter, I will have a 220V 30amp to my mining room. One thing I can not seem to wrap my head is that if 220V have 2 hot of 110V legs and only 1 is being monitored, how does it able to monitor entire current for the pdu? In my case I am going to use a pdu with L6-30P PDU? I thought I needed 2 meters to monitor

bernelnery
Автор

Oh and spacegoats u need to put on end clips on these videos bro'da and a subscribe watermark was well would help. I was trying to veiw the next video and i had to manually. hope It helps

cryptokarnage