HOW TO BUILD A CONSUMER UNIT🔥🔥🔥

preview_player
Показать описание
So today i am going to show you how i go about building up and prepping for this consumer unit replacement. I build it this way to cut down on the amount of down time for the customer.
its a Fusebox consumer unit with SPD and RCBO's


Click here to follow us on Instagram

-~-~~-~~~-~~-~-
Please watch: "HOW TO INSTALL OUTDOOR LIGHTS - WIRELESS SWITCHES EASY INSTALL"
-~-~~-~~~-~~-~-
Рекомендации по теме
Комментарии
Автор

I saw that grommet strip at the Elex show - it was Q Crimp, new product line coming soon - it’s reallly good and holds on really well - just clamps on and stays there

snail
Автор

Nice tutorial. I think the blanks would be better placed between the RCBOs to stop heat build up. RCBOs get warmer than MCBs for some reason.

sergiofernandez
Автор

20A C curve is generally what we have had to install (as per designer) for AC condenser, we might even get instructed to install a larger 32A D curve, subject to size of motor/fan, again as per designer.

barnsley