Basement Bathroom Plumbing Layout Rough in Plumbing DIY Layout

preview_player
Показать описание
This is the rough plumbing for a basement bathroom addition. I had to redo some areas so that is why there are some couplings. The layout will pass upc code for a standard bathroom with tub/shower
Рекомендации по теме
Комментарии
Автор

I cant believe this passed inspection. Never would have in MA.

ptech
Автор

Pretty intense layout. I have a small 10' 8" x 7' 11" area that is more of an L shape to work with. This is before framing. After ripping out drywall, none of the studs are load bearing, just tacked to the side of the joists. Almost did a cartwheel because that means I can delete outright and not have to die. With that gone I might have a 7'11" x 7' and change box to work with after entering the doorway. Gotta find a way to fit a 60" corner tub and a walk in shower in there. I'm going to vent like that as well. Vent is at center of house and new bathroom will be at a corner. Just going to run some 1 1/2" to the corner and 90 back to the vanity drain. I got vanity at top, tub and shower next, shitter last on the line toward the drain. All wyes angled into a main pipe for max flow and the least opportunity for poo water to backup into the other facilities. I need to figure out how to put the backwater valve in. So important. If we were ever in a prolonged period of no power, lets say from a solar flare, wastewater would back up at the neighborhood level. Sewer mains would eventually become saturated and the poo has to go somewhere to alleviate that. So folks without a backwater valve would be the recipients of everyone's doo doo. That is just one extreme example, but hey.

Kudeghraw
Автор

Pause the video at 0:39
Right where your finger is. The vent 90 that comes up out of the floor is illegal. All dwv fittings below the flood rim of the fixture must be long turn or long sweeps. Same thing. Also the sanitary tee that connects both vents together is backwards. Wet venting is also a big no no.

tonybruno
Автор

The vent TY where the toilet is, is installed backwards. The TY should be installed in the direction of airflow. In this case the 90 of the TY should be going to the left.

cassh
Автор

Your your sanitary tee that you using to wet that the toilet and the vanity is actually installed backwards.

brandonmurphy
Автор

Some fuc-ed up wet vent system, no vents!

marqueemark
Автор

You can use 3x2 reducer instead of those funnels

JohnQ-xy
Автор

The vent on your shower trap is illegal. You have a horizontal vent below the flood level of the fixture served.

someguy
Автор

Whts tht cost, I jus need at single shower an toilet

coreykelley
Автор

There's a reason why license plumbers get the money they get where do I start with the things that should have been different. At least where I am in New York state.

ricklee
Автор

Hi you doing . How much a plummer will charge for doing that job rough plumbing?

CarlosbetoGonzalez
Автор

$10 000 on WHAT! that rough in your looking at no more than 5K.

hlneira
Автор

Not trying to put anyone down, but this will fail inspection right away.

INTIMIDATOR_
Автор

Save 10.000 now and spent 50.00 after.😂😂

robertodominguez