Kaycan Vinyl Siding Installation Tips: Overlapping

preview_player
Показать описание
Proper Vinyl Siding Overlapping

Рекомендации по теме
Комментарии
Автор

I saw at least 2 mistakes. Never nail a piece of vinyl that close to the factory, I always stay at least 6 to 8" from it. Also, you have to overlap that more, it has to tuck underneath the left (in this case) factory. If it doesn't, you will see house wrap in sometimes less than one season. I would rather have a joint that doesn't look spectacular than see tyvek exposed. Which do you consider more of a problem?

spacetimeworm
Автор

My opinion you want to over lap past the factory a half an inch when you do it this way if somehow it slides to the right or left it will come off from overlapping then the two ends will butt up and buckle I’ve seen it plenty of times replaced a lot of that

lorenkoska
Автор

Although it won’t move that far because the nail slots are only an inch but theoretically

lorenkoska
Автор

Some factories are 2 inches some are an inch and a half so if your overlapping half that 3/4 on each end it can still slide 2 1/4 inches one way or the other and all it will take is 3/4 of an inch of movement for it to not be overlapped anymore

lorenkoska
Автор

I have been told that the correct way for overlapping, is that the nailing line ends of both pieces are just about 1/4" away from each other. And it makes sense to me. That means about 1" to 1 and 1/4" of the one piece under the locking line of the other piece.The way this video is telling me how to overlapping it might cause the sheets to come off the overlapping and or become bulky.

Elovess
Автор

What state are you in. The factory ends should overlap. Even. So is the factory is a 1 1/2 it overlaps the other panel a 1 1/2 ! 2 in factory overlaps 2 inches. In northern Ohio. You siding would blow off the wall! With the wind off lake Erie. And going from temps of 90 in summer to -40 at times. It wouldn't last one winter!!! So before claiming you way is the right way. Check all you facts first!!!

stevenpellegrino
Автор

These Mexicans I work with they keep saying it has to overlap around 1 & half.. that's like half an inch between the nailing slots

guichozuniga
Автор

My boss had the nerves to tell me that ur suppose to Overlap 6 inches

Jmafia
Автор

You neglected to explain how to trim the ends when you do NOT have a factory end.
You just assume that one always has factory ends or that everyone already knows how to trim them.
NEVER ASSUME !

Bonjour-World