How To Install Ground Earthing | Step by Step

preview_player
Показать описание
This Video Show you How its fix earthing for house electricity

Рекомендации по теме
Комментарии
Автор

Dear Friends...Please Support Our Channel and SUBSCRIBE

CraftVillage
Автор

This is not a proper type of Earthing. Don't follow

pvnsharma
Автор

Please give details in the form of drawing indicating depth of pit, size of pipe, depth of layer of charcoal and salt for easy understand ing procedure of earthing.
Also indicate electrical codal guidelines and specifications for making arrangement for earthing connection.

shetemaroti
Автор

I dont think this is proper earthing method.. First of all, what type of connection earthing are planning to do? Also, it needs minimum 2.4 meter copper/steel pipe with proper 1.2meter x 1.2meter excavation. There is not necessarily to put 80 kg of charcoal. There are lot of advance methods are available like bentonite to provide adequate shock absorbing power. The way you briefed above should be clear for viewers to understand what are you trying to convey to professional. Thank you

ranjith
Автор

We like this, but not telling anything, how lengthy pipe, width, height and depth other things

srinupani
Автор

This is Wrong Method Its Only For Kids

returntothetruth
Автор

Minimum earth pit deep 8feet and charcoal 80kg. And salt 20kg. For good earth value. As per government ohms law value is below 1ohms

hameedahmed
Автор

Kerala voice? There is no voice no commentary no sub title.

stevenphilip
Автор

Hi, can I make the pipe earthing near my plastic water tank ?
Will it be safe?
Please reply

ajaysharma
Автор

Dont follow this Earthing, this is not a proper earthing.

Pangrak
Автор

Solt veyaledu &concrete not used in earthing

maheshjadi
Автор

Wrong Method.
Charcoal should be provided first at the bottom of the GI pipe then the pipe should be buried. And the layers of charcoal and salt should be applied.

ankurpaul
Автор

Dear friend its very bad video because earthing tools 1G pipe or copper plate , salt, charcoal, water soil

kareemabcd
Автор

a lot is wrong with this video, please don't follow

gbengakolawole
Автор

YOU SHOULD STUDY BEFORE POSTING , THERE ARE MANY PROCESSING...USING COPPER, SALT,BENZONATE POWDER &SO ON

salesmatrooshi
Автор

This is not perfect earthing.don not follow this

subramanians
Автор

dalna chya dal dya ish earth ka valu vi nahi milaga

sufiyanahmed
Автор

This is bad electrical work.
First should be copper rod 5’ or 4’ minimum
Second it was still loose after you hit it in with the rock ( gotta be kidding)
Third ground is too dry

ventronics
Автор

Aaisa ghatiya tarika dont follov this is not propar erthing

dineshkucha