16 feet span Beam Reinforcement Details | Beam size details | BBS of Beam

preview_player
Показать описание
16 ft span Beam Reinforcement Details | Beam size details

WATCH MORE VIDEOS HERE:

Construction cost of 800 sq ft House in 2021

Construction cost of 1200 sqft House in 2021

Construction cost of 1500 sq ft House in 2021

Construction cost of 1000 sq ft House in 2021

Construction cost of 2000 sq ft House in 2021

Construction cost of 900 sq ft House in 2021

Construction Cost of 600 sqft house in 2021

Construction cost of 700 sq ft House in 2021

Construction cost of 500 sq ft House in 2021

..............................
ABOUT US:
DHARI ENGINEERS & ARCHITECTS is one of Patna's most renowned engineering Firm, provides comprehensive architectural design services under one roof.
.
Contact us for Complete Residential and Commercial Planning
.
FOR MORE VIDEOS, PLEASE SUBSCRIBE OUR YOUTUBE CHANNEL AND SUPPORT US
.
Like us on Facebook
.
Follow us on Instagram
.
.....................................

Disclaimer - This video is for educational purpose only.
Copyright Disclaimer under section 107 of the Copyright Act 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing
Рекомендации по теме
Комментарии
Автор

Hello sir.... 15*15 hall me 9"*15" column me 4 baar 16mm 4 baar 12mm diya h or beam me 3 baar 16 mm at bottom and 2 baar 16 mm top and 2 xtra at top and 12 mm... And center me 16 mm ke 4 pc se hidden beam diya h ye safe h kya. G+ 2 ke liye. 🙏 plz reply 🙏

LalitSikhwal-vo
Автор

Hello sir... Mere hall ki size 15*14 h or column 9"*15" jisme 16mm 4 sariya and 12 mm 4 sariya diye h... Hall ke beam me 16mm ki 3 sariya bottom me or 16 mm ki 2 sariya top me strip 4" center to center h or center me 1 hidden beam diya h 16mm ki 4 sariya se... Slab me 10mm use kiya 2 baar me G+1 building h ye sahi h kya

LalitSikhwal-vo
Автор

Are 12 mm 4 bars and 10 mm 2 bars enough in a 9*15 column..?

The column to column distance is 15 feet.

How many storeys can be built with this much reinforcement..?

krishna_raj
Автор

Sir G+2 ke second floor main, 17 ft spam 2 bar 12 mm at top and 3 bar 12 mm at bottom with 8mm strip at 150mm, 9*12 inch beam provide karsakte hain Kiya?

ahmedzohair
Автор

Hook 90 degree tak hi hain. 135 degree hony chahiy.

hksharma
Автор

Bahut achaa..
Best idea...
From Assam

lbthangngew
Автор

Sir, for G +2, Is it safe to make a hall of 16'× 16' using four RCC columns in corner, each column size 9"×15" with six 16mm rods; and beam of size 9"×15" each beam having six 16 mm rods, plz guide?

santoshvaidya
Автор

Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??

dreamer
Автор

Sir ye jo aapne latak beam ki depth batayi hai 9×12 wo slab ke saath hai ya without slab.
Agar kisi ghar ki slab bina latak beam ke dalte hain aur same utni hi badi latak beam ke sath dalte hain to slab casting ke baad dono slab main kya antar aayega please reply

Truelines-oe
Автор

Baiya 16 fit distance ho gya 2 collom ke bhich kay sariya dy

ganeshshindemahol
Автор

Centre to centre 18 ft span ke beam me kitne no. Aur kitne mm ka bar dena chahiye(beam size with slab 9x18)

cartooninhindi
Автор

16 ft length beam must have 16 inch depth in stead of 12 inch depth

sureshmohapatra
Автор

16 feet beam me kya reinforcement hona chahiye?

trading
Автор

Informative video, keep it up .
Is secondary beam necessary?
And can I place the ends of beam on 9 inch brick walls from both sides ?

umarrahim
Автор

Sir 16 by 16 feet room me footing ka size kitna hoga

sushiltripathy