Numerical solution of subcooling and Superheating vapor compression cycle.

preview_player
Показать описание
After watching this lecture, you will be able to solve problems based on subcooling and Superheating vapor compression cycle.
Рекомендации по теме
Комментарии
Автор

I was afraid of this topic.
Before getting to this lecture😂

Thank you go much it was helpful❤

itsmechanical
Автор

thank you so much, such an easy and nice explanation, helped me a lot.

rockerjain
Автор

Request to upload the work sheets for the benifit of the viewers.

dwarakakrishna.v
Автор

Thanks for the explaination sir👌but I have some uncertainity on 11:17, where you had to find T2 by relating S1 equal to S2 and I clearly get that, the thing is when looking at the T-S diagram T1 is greater than T1' (hance temperatures are difference) from that being observed. How come you used the conditions (i.e. sg) at point 1' where the temperature is 263K? since the the process from point 1'-1 is not isontropic, I was hoping we were going to first find temperature/conditions at point 1. If there's any logical explanation for the method, please clarify it Sir.🙏🙏

xfcsprince
Автор

Hello, here refrigerating effect will be T1 dash - T4, T1 dash to T1 is superheating process so do we consider this as refrigerating effect

shrirangkelapure
Автор

hi sir,
In the previous numeric problem on finding COP you have considered degree of superheat and sub cool as Evap temp-degree of superheat, similarly Condensing temp-degree of sub while considering Delta T ( temp diff)
But in the above lecture you have directly put delta T as degree of superheat

please clear the doubt

mahendraprabhu
Автор

if s1=s2 then how did you just simply added everything?
and how did you added 267 kelvin and 7 degree Celsius?

mobigamez
Автор

Can you explain the subcooling correction for the following, R404a, SST : -31.67°C, SDT: 40.56°C, Compressor Suction Temperature : 3.62°C, Liquid temperature : 9.57°C, Degree of Superheat : 36.53°C, Degree of Subcooling :30.99°C and refrigerating effect ( cooling capacity) : 6710 watts..i need to correct the capacity to zero( 0 ) Subcooling from 30.99°C..Can you explain ?

Ratna
Автор

How did u calculated natural log in entropy equation

santhoshavsk
Автор

For every model of this problem we can do like this?

pujithak
Автор

while calculating COP superheat part is included or not

shashankmukhi
Автор

Can you explain the calculation for subcooling correction ?

Ratna
Автор

I have a question on Mass flow rate calculation. How to calculate it if refrigerating capacity is not known?

manoj
Автор

Hi just want to confirm u have taken COP h1- h4 not h1' - h4

shashankmukhi
Автор

In standard while calculating T2 you took S1=S2 in a different way and in this different

sahilparmar
Автор

Sir can you upload a lecture making the above calculation using Coolpack software?

agordat