How to dismantle air condition outdoor unit without gauge.

preview_player
Показать описание
Step by step ( 10 steps ) pump down operation guide line for air condition outdoor split unit.
#aircondition
#outdoorunit
#pumpdown
#maintenance
Рекомендации по теме
Комментарии
Автор

This gentleman is to be thanked for the effort of making a video. The technique has many flaws. Use a proper spanner set not an adjustable wrench as the caps can be very tight. Also, with the other hand hold the valve stem with an adjustable wrench when you remove the caps. Pipe stems can bend and even brake, something that this gentleman is ignoring.The air con unit must be placed on COOL setting not heating setting BEFORE you decommission the external unit. Run for at least 5 -10 minutes. If possible place an air heater in front of the internal unit to warm up the evaporator coil. With the hex key break the seal (as the valve will be fully back seated) of the liquid line (HP) valve (1/4" pipe). NOTE at 2:22 in this video when he closes the liquid line, the copper pipe ices up. This tells you that the liguid refrigerant in the pipe is now evaporated. You need to allow all the liquid to evaporate. Run for a few minutes. He runs it for under 2 minutes. may not be enough. You will hear the compressor noise changing as it sucks all the vapour in the compressor circuit. You need to give the liguid refrigerant time to evaporate(in the evaporator that is why the heater will help). Close the gas vapour valve (front seating it) (LP)(5/8" pipe). Ensure both valves are tightly closed. Don't overdo it. Remove the copper pipes and IMMEDIATELY place masking tape to fully cover the valves and the pipes!!! Do not use bubble wrap like this gentleman did. NOTHING must contaminate the pipes or valves. Place the caps back on. Also useful to bring a spray bottle of soapy water to spray on the valve once it is closed to check for leaks. The professionals will use a manifold to decommission the external unit. It allows you to monitor the gas flow and to understand if there is more liquid gas in the evaporator. If the unit is very old it is possible that the valves leak. when you break the seal at the beginning, place soapy water all over the valve and see if it bubbles. If it does. Place the caps back on and call an HVAC pro. Allowing air to enter the condenser when pumping down means that the gas must be removed and disposed of and new gas introduced.

redpost
Автор

Alternate title: "Man takes 5 mins to realize a Hex wrench works on both ends"

DiscoFang
Автор

Congratulations sir. Very useful this video. Thanks a lot for taking your time to share this valuable information. Thanks

ivispimienta
Автор

new siding
You just saved me some $$$$..
👍thank you👍

mikekeating
Автор

Tnx bhai aapki help se aaj maine apne 1000 ₹ bacha liye without mechanic

aneshchopra
Автор

Thank u I learnt something from you I did try to remove the unit in a different way and did not work now will use ur video ...

VernonGovender-dbtg
Автор

Oh, for goodness sake, use the long end of the hex wrench until you have to tighten it. Jeez. Like watching paint dry!

isumiterracetv
Автор

thankyou, very simple, and very clear to understand

johnjosephpuntual
Автор

Thank you very much sir, how many times I'll do it myself to dismantle the aircon but i just only remove the cap and close the valve, and the freon gas is out very noisy

buhayjapanvantiw
Автор

anna amazing explaination step by step instructions very thanking sir

SenthilKumar-gzll
Автор

Thanks for helpful video
Love from Nepal

punampandit
Автор

You have done good job, thank you very much for detailed video.

ariansinanaj
Автор

I see in the Bahamas where I live the close the big line first then turn the ac on let it run for about a minute or 2 then turn the unit off then close the small line

garvinjohnson
Автор

May i ask you sir i have plan to transfer my AC to other room with by my self. Can i just reconnect the two pipe and cup then reopen that 2 supply? Or can you tell me what to do for Reconnecting? !

ryel
Автор

Good job Sir kahit walang audio pero malinao

jordanoliveros
Автор

It is a good video and a huge thank you for it but you can use the long side of the alan key too. :)

krisztianbalazs
Автор

very good job, please add audio. Rated number 1. Best ever. Thank you you my $500
I would like to send you a gift certificate.

Gganp
Автор

Video helped a lot. Just have a question. Is the proccess the same to re install it ?? Or it needs to by done by a pro with special tools ?

DomGR
Автор

i just want to change the direction of my outdoor unit can I do it myself, now you have shown how to unplug but how do I reconnect this back?

mdabdulmoiz
Автор

Good video Sir. Is it required to switch on the ac power before dismantling?

hlalthanpuia