TIA Portal: External Peripherals / Distributed I/O Shared Devices

preview_player
Показать описание
How to use an ET200 in TIA Portal? And how to connect it to multiple PLC's and share it?
Find out here!
If this video helped you, please consider helping me by joining my "GoFundMe" and donating a small amount to my cause. Link here:
Рекомендации по теме
Комментарии
Автор

Thanks for this great piece of work...I'm growing my Automation career thanks to you

disrael
Автор

Super explanation, I like your way of teaching.

firasn.t.
Автор

nice video i have learn a lot of things with, just for informations: to connect the two PLC we need PN/PN coupler.

sarahlabidi
Автор

you are actually amazing person and thanks a lot for the valuable content you share

OT_ICS_Cybersecurity
Автор

I love your to understand and follow up.
Make a video on Shift instructions in future thanks in advance

simonmax
Автор

Always a pleasure to see such qualitative video!

MrMouais
Автор

13:43 PN Coupler must be used to connect 2 CPUs with same IP and Subnet.

ghosthunter
Автор

Hi, why is the connection colour between Plc an ET200 different in each case?

karoliczanwojtylanu
Автор

hello hegamurl . in the actual state of this video with two different plc and one shared i/o device ; how to do if we want the twon plc to be able to excange informations together ?

souleydiallo
Автор

Where ist the donation link or patreon?? :D:D

dukenuke
Автор

is it possible to share the same module with 2 plc's? for example if we have a 16xDI module can we split it and give one byte to one plc and the other byte to the other plc.
thanks

georgekoutsoudakis
Автор

Hey If I share both inputs and outputs for both PLCs and keep only one plc active at a time, will this setting work? I'm trying to acheive Redundancy.

amaljohnson
Автор

Thank you very much sir for the information..more power to you.

reylepiten
Автор

I'd like to know about pointers ans any pointers, can you make a vedeo about it ?
Your vedeos are amazing, keep doing this great job.
Thank you.

joaoalexandrecorrea
Автор

I have one 1500f cpu having failsafe io also normal io on failsafe
Other than that I have a 1511T processor i cannot connect the normal io to the 1511T processor due to mounting.

Can i read non failsafe io in 1511T which are connected to failsafe CPU

vaibhavkul
Автор

How to share io devices with 2 PLCs. For eg 1 et200sp has 3 di and 2 dq. Now I want to share this et200sp completely with both PLCs. Means PLC 1 and PLC 2 both can access all 3 di and 2 dq.

MukeshKumar-oxuz
Автор

How those devices are connected to each other? PLC_1 is conntected to ET200 (port 1) and PLC_2 is connected to ET200 (port 2)?

intradeee
Автор

Hi.
If you can please make clip about cpu redundancy.
Thankx a lot.

saeedtube
Автор

Rockwell automation Allen Bradley is more easy then Siemens, more easy and friendly user but most people do not know

lowidarwish
Автор

Thank you for your video, but I have a question: How do PLC 1 and PLC 2 connect to the ET200 (physical connection)?

ngoctuannb