How to use a multimeter on dryers and outlets

preview_player
Показать описание
In this video, Marcus will demonstrate how to use a multimeter to check outlets and the connections on a dryer
Рекомендации по теме
Комментарии
Автор

I love it when the video is straight to the point and short. Exactly what I needed!

BettiesFactsNoFiction
Автор

Straight forward and to the point. Thanks!

andrewj
Автор

Very helpful. I did the first test just to discover one of outlet wires are faulty

zazarox
Автор

Wish you had showed doing it on the four prong outlet. I don’t know what you mean by testing both legs and testing across. Guess I’ll go to another video.

honeybeesoup
Автор

240 is deadly. Marcus is a pro. All others should be wearing insulated gloves. I did something similar to this when installing a baseboard heater, made an errant tap with my probe and blew the tip off with a pop that made my ears ring and probably scarred my retinas. Be very careful with this video.

m.scottpalmer
Автор

You have your red probe plugged in the ground(common) plug. Black goes in com, red goes in batt for standardized measurements

QueensPirate-qhhi
Автор

Tested mine and I got 124 for individual test and 243 for both combine I’m guessing that’s fine since it’s not below the numbers you mentioned

sschriver
Автор

What do u put the meter on all u ever say is the ac side what number 300 200 20 2 which one

bigdclarksongaming
Автор

Can we see a video for testing the thermal cutoff switch for the dryer? I remember the setting for the meter but want to see which spots to test and how to tell if bad

ronniewilliams
Автор

does it matter which color probe you stick to the neutral?

illskillz
Автор

What if I get no reading from the neutral to the hot but get one from the ground to the hot?

goldenboyproductions
Автор

When testing both bottom legs on a 3 prong, I’m getting a reading of 240. Can you help me understand why it differs from the 200 as stated in your video?

MZuberi
Автор

This video leaves too many questions unanswered. The comments before mine demonstrate that. Oy

lnat
Автор

I just replaced the 3 prong Receptacle. When I check each side with the neutral. Each side has 120, but when I check the cross( positive and negative) at the aame time it does not say 220. It zeros out or says 3. What could be the problem?

papasmirf
Автор

Why is the red probe in the “COM” side?

kiddd
Автор

When testing a 3prong. You get 110-120 on each side, but dead across the 2. What could cause that?

Joeybagofdonuts
Автор

Do we have to have the power on or off before doing this

bernardoavila
Автор

What’s wrong with my dryer plug if it doesn’t test 240 just 120

ruehtir
Автор

On one of the legs I get 0. Does that mean it’s broken

Yaaalalala
Автор

What if you git 120 volts but when you test both legs together you git nothing? Outlet or breaker?