The project to renovate the electrical wiring system has just been completed

preview_player
Показать описание

Рекомендации по теме
Комментарии
Автор

Love how the data is extra shielded when it crosses powerlines. Just perfect.

nutterts
Автор

No facemask to protect against all the dust, you should really invest in those it will save your life when ur older

casperas
Автор

If in my country electricians was smart like this my house would be safe. I am done roofing and only wish for smart work like this.

boxoffisa
Автор

Hello....I admire the electrical job you do

williamberzunza
Автор

I enjoy watching your work, its so satisfying watching a master at his craft 👍👍👍

sedric
Автор

Beautiful work as always! I have a couple of curious questions. How do the conduits that meet at a right angle between the floor and wall stay flush during finishing? Also, how will the floor be finished, given that you had to cut away a lot of it?

huyanh
Автор

Thanks for explaining the conduit colors!

joeshobbies
Автор

Love to see your work 😊 I sometimes wonder where or how to place e.g. the transformers/drivers for LED-strips or similar embedded in the ceiling or walls, if it is not possible to place the transformer/driver in the ceiling or attic. Is it in a specialized, accessible box in the wall, and do you run wire or conduit from the LED-strip to that box, or?
Also, how does the junction box for the network cables look when fully wired and connected?

jhdk
Автор

How are you laying the conduits from the lower floor to the upper floor ? Want to see how the pupes pass from the ceiling to the above floor ?

sanjaysachdeva
Автор

good work but I think cleaning them is overkill they will pour cement on top so just passing water on them to get rid of the dust should be fine

Tovaritch
Автор

Do you only run single circuits in each conduit? If so why not run multiple circuits per conduit like we do in the US?

jacobkeck
Автор

Same size conduit on appliances? Like for 30, 40 and 60 amps ?

shamusdavis
Автор

Do you wash the conduit with the cable inside? Sorry just asking.

alvinaugustineanthony
Автор

I have a question. Is the only reason you use small conduit that the floor is too low or are you worried about induced voltage

seventhnightsurvivor
Автор

Will under floor heating not effect those conduit with cables?

altintahiri
Автор

3 wires: Live, Neutral, Ground Earthing

fuadizharuddin
Автор

Do you have 3 phase connection for example for induction stove? Is it also in a single red tube?

lolkusus
Автор

Who ever making working videos are you apprentice for sure

sadmanador
Автор

Tôi sẽ không lựa chọn đặt ống dưới sàn nhà, tôi sẽ từ ở trên xuống ( như vậy sẽ không bị ướt dây điện)

Luongnguyen-jtdn
Автор

His shirt is inside-out for a portion of the video, then right for the rest.

jonathanpayne