Simple Earth pit resistance test (how to test it) | Earth Tester | Earth resistance Tester

preview_player
Показать описание
#earthingtest #earthpittest #earthtester #SustainableEveryDay

If you are targeting Solar Industry jobs in Dubai , then this might be "SUPER helpful"

Learn all About Solar Plant DATA analytics & advance report creation:

Digital CV creation for Dubai JOBS on Solar PV Industry:

For Questions/Technical support connect with me.

Earthing test
Earth pit
Earthing
How to test earthing
How to test earth resistance
earth pit testing,
earth pit testing in tamil,
earth pit testing in hindi,
earth pit testing with megger,
earth pit testing in telugu,
earth pit testing with megger in tamil,
earth pit testing methods,
earth pit testing meter,
earth pit test procedure,
earth pit test value,
how to test earth pit resistance,
earth pit megger test,
how to earth pit test

Рекомендации по теме
Комментарии
Автор

Kafi informative lag raha tha, mahar mujhe to yeh samaj mai nahi aya khi yellow wire kaha se shuru hoti aur kah stop..Pls😮

jameszosangliana
Автор

Sir please hamen yah bataen ki hamare solar plate dhone se platon ko hath lagane se current padta hai

tabasumali
Автор

Sir you said that resistance should be less then 5 ohm but here is 12.6 ohm?

technicalthinks
Автор

3 wires connected together and 1.25 ohms substract... is it right procedure?
Is it as per IS?

ramanactive
Автор

Earth Pit 1 = for ACDB & Inverter.
Earth Pit 2 = for DCDB, Panals & structure.
Earth Pit 3 = for Lightning Arrester.
Is it proper way to do earthing for 3kw solar plant?

manusharma
Автор

Hi
Can. We use this instrument to check underground water for bore well

anaspatel
Автор

Sir, if I want to measure the resistance between 2 wires (BSNL for ex 1km ) will this meter support. If it support at which I have to connect Plz reply me

satishgajini
Автор

my doubt is, it is necessary to fix both p2 & e2 in a same direction, then your answer is yes means, what will happen if we fix that auxiliary electrodes in a oposite opposite direction .can you please clear me

maruthupandi
Автор

Spikes jo E2 aur P2 ki through he kya earth pit k series or line me lena he ya kahi bhi lagaskte he bas 10m or 20m from tester ??

syedmohammadsaif
Автор

Sir oms ya mega oms hona chahiye.wese kam se kam 1megaoms hona chahiye kya bis k anusar.

Manavsain
Автор

Sir which type of glouse are you using please tell

sjcreation
Автор

Kyy load connect ho tab resistance check hoga???

truthbolo
Автор

Hi sir, You have taken the distance from E1(P1) to P2 as 10m and then P2 to E2 as 10m again. But in the connection diagram of the earth tester it's 0.62 D and 0.38D, which means they shouldn't be equal.

avin
Автор

Thank you sir for your video,
Why you subtract 1.25 from main value

gourangasasmal
Автор

hello sir how are you please can you share with me the prices for those earth tester meter

otimalfred
Автор

Tin taar ke baare me kuchh information dijiye na

sujitkumar
Автор

Sir ek baat bataiye pls meri earthing ki reading 0.2 aa rahi h to kya galat h

tpgaderiya
Автор

Nice information. Also tell about the value of voltage between Vm3 Inverter solar input points to ground value .

abdulnafayawan
Автор

I don't have an earth tester. Is there a way to test it with a multimeter.

IndPolCom
Автор

Thanks for your video sharing its very informative, i want to ask one question in this case we get resistance of 12.16 ohm how we will bring it to 5 ohm ? awaiting for your valuable reply

trimafs