How to connect to a relay to use PCM600 and find its information?

preview_player
Показать описание
This instructional video will guide you through establishing a connection between protection relay and engineering tool PCM600, and finding out critical data. Check the content below for direct access.

Content:
0:07 Fundamental Relion® family protection relay engineering concepts
0:26 Establish the physical connection
0:47 Enable communications between the relay and the laptop
1:25 Manually change the laptop's IP address to one that is on the same sub-network as the relay's IP address if you are using the rear port
2:08 Set the technical key
3:03 Find the relay's serial number
4:28 Find the relay's information with the web HMI
Рекомендации по теме
Комментарии
Автор

Hi, can we connect to front port from remote network ? (not same subnet)

ZirveAzeri
Автор

Hi ABB, can you please make a video on how to set the reclosing function (DARREC) of RER615. Also, in the phase and ground directional settings, is changing the curve types requires the change in the parameters (A, B & P)? For Schneider and SEL relays, the curve type does not require the change in parameters except for customized curves. We've done a SCIT, but the actual trip time does not match with the computed. Also, the reclosing function isn't working. Whom can we contact for our technical inquiries? Thank you.

Christopher - Philippines

christopherserojano
Автор

REF 615 Communication is established but when I tried to read from the relay, it started reading but suddenly stopped and showed a cancelled message.

NB:
I'm accessing the relay using PCM 600 2.11

shijogeorge
Автор

I had connection with new ABB Relay RET670, there is green signal as shown(no any red cross), this means there is sound connection. But when I tried to read for the internal configuration of relay setting in order to check and modify as per our requirments, while using read option or write option, it cant read issuing . It issued
:Configure IED first. with remarks Cancelled>

is there any configuration still do be done, what exact configuration is it looking for.
At some point it "common read/ write menu", it comment section while writing it issued error at application configuration point and then signal matrix error(just flash for very short time which i got by using camera video mode to get what exaclty happened.
But I coudnt configure the source of exact problem.

sandeskunwar
Автор

Hi, In REF615 relay trigger continuously breaker on and breaker service signal in the disturbance record how can we stop continuously triggering, I need one trigger only at the time, kindly give the information, thanks..

ILAYARAJAraja
Автор

Hi guy, Could you tell me How did you do to setup PCM600? I don't find PCM600 driver. Thank you!

mothanhattran
Автор

Hay ABB
I have a problem with relay ABB RET 650..
I used PCM 2.10 600 to connect with relay but the path is not of a legal form..
I need problem solving from you.
Thank you

paulinadukabain
Автор

Hello sir, i am not able to use "work online" mode in PCM600. The "work online" tab is showing deactivate, please guide

bharatlalmali
Автор

Hi Abb Can I get Arabic subtitles for the video

hassanpropro
Автор

Hi..How can I access the application configuration/signal configuration in REU611 through PCM600? I was made to understand that the signal configuration can be accessed in both web HMI and PCM600 as per video in link below:-


However I couldn't find the options to get to the application configuration in the PCM600 for 611 IED series. Please help!

lebonsbons
Автор

Where can i find REB670 technical key?

rohitrhtx
Автор

Hello dear
Can help me about point list ref 615 modbus register address mapping.

mahdeyousif
Автор

How to do manual syn enable in REF 615 relay

ILAYARAJAraja
Автор

Menu-control-CBXCBR, this section not getting access to close BREAKER, I need access to close from this section, what I want to do to,

ILAYARAJAraja
Автор

hii ABB,
I need help, Username and password Administrator WHMI REF611 ABB. Factory default password or shall we set it.
Hominhduc- Vietnam's
Thanks.

H.M.D_support_ABB
Автор

wrongly said DHPC service instead of DHCP Dynamic Host Configuration Protocol

ranjithkumar-ynum
Автор

what is the password for web ADMINTRATOR in the browser ?

nguyenvantung
Автор

Hi abb Can I get Arabic subtitles for the video

hassanpropro