Wheelock & Fire-Lite Voice Fire Alarm System Test 20 | We Have Troubles!

preview_player
Показать описание
Today's system test on the voice evacuation fire alarm demonstration board brings many changes to the devices, messages, and panel settings. One of these changes causes two new troubles on the Fire-Lite MS9200UDLS fire alarm control panel (FACP). Thank you for watching, subscribe! :)

This is my other channel, subscribe to see some wild wilderness adventures:

#systemtest #firealarmsystem
Рекомендации по теме
Комментарии
Автор

If you notice closey, you can hear how fast the panel piezo activates when he pulls the pull station's compared to when he has the system on clip on older systems. This is the benefit of newer addersable protocols as every second counts in an emergency and the every second faster the system activates, the faster the emergency can be resolved. While it may not be a huge difference on this small system, on a system on maximum capacity, it will be a huge difference.

captainchris
Автор

The BG10s don’t deserve to be hated I don’t even have one of my collection. I still want one.

Dilsonalarmsandelectric
Автор

What a neat system test! I enjoy hearing those E50's, a lot! Nice one, Grant!

TFEAS-
Автор

How do you set up the voice evac ? do you need the 9200 UDLS panel? just the speaker? currently have an SK-4 panel wired in my house. haven’t worked on this in YEARS

rdswatteam
Автор

In my experience lightspeed protocol has caused more harm than good with many systems especially with type A SLCs. Often times the constant pinging of each device develops issues and I've noticed that the EOL resistors have actually died from it.

On a previous project for a manufacturing facility, they had over 2 dozen SLCs and the EOL resistors had all failed somewhat back to back over the span of a year after the ping rate was increased to the max setting.

We couldn't attribute it to one piece of faulty equipment because the SLCs ran on a lot of different control panels linked together as well as extenders on each to prevent a voltage drop in the pings. We went to that location 5 times before we finally reviewed the maintenance history, and then it hit us. The resistors that failed had overheated, presumably due to months of handling rapid data pulses. We ended up replacing the resistors on each of the SLCs and reduced the ping rate. Never got another call there since.

Another tachy-ping incident happened on another site during an overhaul where we missed a single pull which thought the constant pings scared it and caused a capacitor to short(thereby eating all signals and making the control panel unable to understand the data. it killed the whole line until we finally found it hidden behind a shipping container.

Bill-bjfn
Автор

Hi S.E.R Safety 👋. I have a question. Are you able to replace the current Fire-Lite annunciator with the Fire-Lite ANN-AD annunciator?

Gachrick
Автор

Grant deserves an award for making these videos. This is a masterpiece.

emirald
Автор

How long have you been making videos? I used to watch this kid with “Sk8r” in the name or something. It was so long ago but he did fire alarm videos exactly like this. It was like 12-13 years ago

rdPlaya
Автор

You can tell how much louder the AS is than the e50 😂

Organham
Автор

Hey, can you do a video on how to wire up a speaker strobe to where the amber strobe flashes instead of the clear strobe and how that works?

randomvideo
Автор

You should make a video on how to program different messages on the wheelock safepath cause I had one and never knew how to

xxmadzombiexx
Автор

My church has this fire alarm system but the wheelock speaker strobes are rebranded by Siemens and the panel is a Siemens mxl voice evacuation fire alarm panel

Calebs_clocks
Автор

Can you do notifier nfs 320
next pls

TheDTechGuy
Автор

I found a document online recently that has some information about my school's fire alarm system. The document said that the district has standardized on Gamewell FCI E2 or E3 I think systems, however, along with the very loud 3 beeps, there is a tone that plays 3 times but this tone is at 1, 000 hz, and after the 3 times it plays, it says "May I have your attention please, may I have your attention please, there has been a fire reported in the building. Please make your way to the nearest exit" then the tone plays again 3 times, then break, then 3 times, and then the female voice again...

BrennerEraFan
Автор

You should the new notifier slow woop tone and voice for the next voice evac test

Kbk
Автор

For the first time use the weatherproof gentex commander

sodas_LisT
Автор

Hey Grant, can you please do a system test with Edwards EST Integrity models, an EST SIGA 278 pull station and an EST Genesis Amber Speaker Strobe?

reffthecanadien
Автор

We have wheelock a.s'ses in my school, in the classrooms.

firesafetyclass
Автор

Those BG-10LXs are only compatible with clip.

Fire-Lite
Автор

The only way you know how many of them will get a job at this rate would depend upon your income

Smokedetor