Basic Programming on a Simplex 4010 Panel

preview_player
Показать описание
Do not tamper with safety equipment, I am not responsible for your actions.

Thanks for watching and your continued support! Don't forget to subscribe!

Do not copy or redistribute any video or channel content without express permission from channel owner.

All tests were done in a controlled environment. No actual alarms were initiated unless otherwise stated. All permissions were granted for creation of these videos. These are created for demonstration/education purposes.
Рекомендации по теме
Комментарии
Автор

No one at my building Knew how to disable the trouble after going into program mode. Thanks to your video, I fixed it and look like a genius. Thank you

nursejoy
Автор

My first elementary school has a Simplex 4010 system. It was installed around the mid-2000s, tied into the school's original Simplex 4208 panel from 1974 (the 4010 was replacing a 4004 installed in 1998, which in turn replaced a Simplex 4002 installed in the late 80s or early 90s for added-on duct detectors.) The 4010 was for main controls, the duct detectors, signal coding and the modular building, while the 4208 was used for the existing pull stations, heat sensors and an old ionization smoke detector. They had Simplex 4051+4050-80 horn/lights, but they used 120-VAC light plates for some reason, and while the NACs on the 4010 would code the signals (Slow March Time), they had to run through the 4208 to provide the AC power for the lights (while the horns were 24-VDC.) But in early 2015, the Simplex 4208 panel started failing (sometimes the signal circuits wouldn't work in a certain zone, or the system would randomly go into alarm), so during the February break they gutted the 4208, wired everything into the 4010, replaced the old 4208 battery cabinet with a couple of EST booster power panels, and replaced all alarm signals with boring SpectrAlert Advance horn/strobes (they even replaced the Wheelock MT-24-LSMs in the modular with Advances!) But at least my city's school district considers faulty/malfunctioning fire alarm systems a top priority on their agendas!

ZakWolf
Автор

This is a wonderful lesson. Thank you!

nebarodrick
Автор

And this video was really very very helpful for me. Thank you boss

enamakram
Автор

What level is required to make the dialer dial a 10 digit number instead of the 7 digit number it was programmed with

chrishoffman
Автор

Nice video! Can you do a video of just how to wire one of these? I think that would be really cool since there really isnt a video in that on YouTube

cmace
Автор

5:30 - I guess you can't... recall?

Fahrenheit
Автор

I got one of these panels, but my level 4 code 4000 won't work. Any ideas how to default the panel and restoring the default level 4 code?

joelschuler
Автор

Need help deprogramming a smoke detector above the duct system.

chinoak
Автор

Good Day sir, I have a question. What is the password to level 4? Please answer i really need to know. Thank You in advance sir. Im from philippines.

ryanmanagili
Автор

Does anybody knows how to get the account number for the phone lines from this simplex 4010?

ulisesocampo
Автор

Hi, I would like to know that would a spectr alert advance connected to simplex panel fry because of different types of current output(FWR or filtered DC)?

DCC--vqng
Автор

The AC power lamp is turning on and off continuously the system is booting continuously

keerthikv
Автор

Kindly make videos for programing on 4020 control panel simplex....

naumannizamkhan
Автор

You could touch both battery terminals with your hand and nothing would happen. 24V isn't enough voltage to break/arc through your skin.

thenextgenable
Автор

At 6:30 whats the name of that pull station

coltonkowalczyk
Автор

Just a question how hard is it to program a audible bypass on the right buttons?

frankspliff
Автор

We are preparing to demo a suite at our business that has 13 smoke detectors, 7 strobes and 2 pull stations. What are your recommendations for disabling the points and listed on our print out of the points list names for these devices.? Post disabling the points, you mentioned the wires are still live. What should we do with the devices during the construction ?

TnOutdoors
Автор

Thank you so much. Can you add a annunciator to this panel.

caleb
Автор

What about march time and other codings were do that i always wanted to know that i just carrious because i might buy a pannel for my own house and have mechanical horns on it

vintagesimplexfirealarmsof