Can I have Span 7.6 meter (25ft) between Two Columns - How to Keep span 7.6 meter b/w 2 Columns?

preview_player
Показать описание
#CivilEngineers
Spacing b/w RCC COlumn
7 meter span for column
How to keep span of RCC COlumn
Рекомендации по теме
Комментарии
Автор

How do you rest the 560 mm width beam on the 400 X 400 mm column which you have calculated?

prabhatkumardangi
Автор

Only one doubt... Beam width is bigger than column width... Will it be safe to carry load... 700 x 500 - Beam size... 400 x 400 - Column Size... 500 sits on 400... Will column show heavy buckling when 50mm on either sides of the beam projected outwards...

gowthamram
Автор

Thank you for your excellent explanation. I always enjoy your calculations and explanation.

lansanah.kamara
Автор

easy explanations yet solid knowledge ! 🙋👌

accsltd
Автор

I have always enjoyed your insightful explanations. This one was really refreshing. Benefiting a lot from it; so please keep it going.

tomusuaquo
Автор

there is not mentioned about concrete grade

tharangarukmal
Автор

Thanks for your work sir. What would be the foundation column and plinth beam design for garage with a master suite above using these beams as floor beams?

akeemfrancis
Автор

i designed a hall for confrance . distance bitween the tow coulum is 12m . and the beam bitween them is 78cm .
is this safe

danaal-barzanjy
Автор

Just work through one example as per the regulation. You can talk about variations after. You keep dotting around from this to that which makes it confusing.

fortuner
Автор

For G+2 building, 7.5 x 7.5 m grid system , central columns will have minimum 2200 km reaction.(Live load 3kn, DL 1.5, seismic zone iv)
So min.size column 600x600 mm
Beam 450x450 will be more than enough....

prmodrwt
Автор

Your very good Engr.. Keep it up and more videos.

Engrferdz
Автор

How the beam of size 560x760 is land on the size of column of 400X400 .

C_Pratical
Автор

On existing Third floor terrace floor
Column size has 450mm x 230mm
Total 8 column
Total three galas
Each gala has, columm to column span is
12'8" x 18' ( note : this dimensions are not measured from the centre to center of the column )
All 10 beams has width 6" and depth 24"

We are willing to increase one more slab i.e. fourth floor slab this would be our last slab
With same all dimensions as above third floor have except beams. Beams would have width 9" and depth 12" on fourth floor
So would it work out
Can this transfer load properly
Waiting for your response

jasminj.
Автор

It doesn't mention any load, if the load case will consider what Will be changes in design after considering the load case ???

kalpeshpatil
Автор

Are you providing the desig services... I need structure designing of my house.

zakrians
Автор

sir, how to calculate the size of reinforcement bar for this case?

kingengrad
Автор

How 560mm wide beam rest on 400mm wide column???😕

fittamizha
Автор

In my case I have a span of 9m between rc columns which size of beam should I use

kondeanderson
Автор

Does the beam depth include the thickness of floor slab...which is 6inches or 150mm.?

isaacamoah-baiden
Автор

Can i use 10 inch width & 18 inch depth of a beam for a
24 ft gap b/w 2 columns ?

AK_.....