Delta to Wye Standard 3 Phase Transformer Connections

preview_player
Показать описание

Рекомендации по теме
Комментарии
Автор

This guy was my teacher for intermediate and advance at George Brown in Toronto back in 2017 I still check up on his videos once and a while. Thanks Peter!

Alex-tdje
Автор

You are the best instructor and Teacher brother. Truly appreciate God for bring people like you who dedicated their passion with the world. Appreciate it for your Humbleness and knowlage that you are sharing with Us

PersianTiger
Автор

Wow, the best video I have ever seen that explain the Transformer configurations included the theory’s and how they connected in simplest way that make people fall in Love with the electrical. Even your tone as an instructor is very calm and very kind . Ohh man I love your channel and you explain everything in a perfect order that your audience will not get confused. Really appreciate it bro ❤🙏🙏🙏🙏

PersianTiger
Автор

Excellent video. I wish YT was available 40 years ago when I started my training. Going to send this one to my son who is also and Electrician. Thanks for posting.

guitarDad
Автор

Great video. I love in the Deep South of the USA. We’re one of the few places in the states with 600v in the old mills. I have worked it once at an old ice house. Most our stuff in 480v now.

johncoyote
Автор

Thank you so much. You’re doing gods work. Trying to diagnose a transformer as a young electrician.. this is exactly what I needed as i knew I could adjust the taps to step down their voltage I just didn’t know how.

daytonturner
Автор

Question. Why do you label H1. H2. h3 and L1 L2L3 not sequential left to right but your color co 13:05 ding is left to right in oer BOY and BRB?

plandl
Автор

The way he explained it the wiring in the video for the high voltage is wrong then you should probably relay that to everyone so they don't get confused other than that really good video

cameron
Автор

Nice explanation👍👍👍

Is it possible to put two cables in one terminal of secondary side, like what you show on the video.
I want to use this method to spilt out for two machine.

Electroplating
Автор

Which of the two connection is the most advantageous in banking a transformer: delta-wye connection or wye-delta connection application in facility with commercial and residential area?

benjaminestebal
Автор

Great video…I’m told that ESA no longer requires the system ground conductor…only need the bonding jumper…can you explain?

rickbotelho
Автор

You have H3 brown, H1 orange and H2 yellow. Shouldn't it be H1: brown, H2: orange, H3: yellow?
Ah! I see in the comments you're in Canada, where you use Red, Black, Blue for 208/120, so presumably you use Orange, Yellow, Brown for high voltage.

icevariable
Автор

Great job. Love the way you explain things. I'll be following you now and watching more videos

bootlicker
Автор

11:30 is that the common core? X2-X2-X2

keving
Автор

So where does the 480/277 voltages come from?

TXRoeJogan
Автор

Keep in mind my fellow Americans confused about the color coordination, this is CANADA's color scheme

DjSeiki
Автор

How would I know what size Transformer I need for the application I need it for? For example I need to install a 6 car chargers what size Transformer would I need?

theseattlegreen
Автор

You’re primary side is connected incorrectly H1 should be brown H2 orange and H3 yellow

Mrmudbone_gaming