Deye Inverter: Prioritizing solar over the Grid see how it is done.

preview_player
Показать описание
Did you know you can prioritize solar over the grid with the Deye inverter? Follow me as I show you how. I also run 2 AC, my Air Fryer and I pull over 11.4 kwh from my panels.
Рекомендации по теме
Комментарии
Автор

I think you found the best inverter. I just love it. Kicks my aims in the butt. Keep up the good work.

marcoa.rosado
Автор

You are an expert in your field Dr Solar

krikornajarian
Автор

Thanks for these great educational posts. I learned a lot from you and actually got convinced to install a deye system. I'm on 5Kw Deye, 2 X US3000 pylons, and 14 X 410w poly panels(east-west orientation form longer stretch of solar power). The system works very well, I'm still adjusting to it. It is grid tied, so when I deplete my batteries at night, it then switches to the grid. I can also export to grid side of the inverter(export to CT). So during the day when the batteries are fully charged and there isn't any other usage, I use the power from panels and batteries to heat up the geyser(3kw element for 150L) or cook using induction stove/oven/insta-pot. At the rate I'm going, my electricity bill is down to about 25%, and it could go down further with more optimizations. So thank you very much.

MelvinPhuti
Автор

I like the Deye inverter ! Once again thank you Doctor Solar for another fine presentation 😎😎😎

burtonnystrom
Автор

Very impressed with the functionality of this inverter. Can I suggest you get a sort of tripod stand for your camera so that it does not shake so much? That way you can go ahead with your presentation. Thank you.

xlgoldfish
Автор

Thanks for this Dr. Just a suggestion that you use a tripod to keep the camera steady. Otherwise very instructive

olatomiwaoyebolu
Автор

One thing noted here on time of use, your setting in the afternoon is 80%, which means the inverter will use the battery up to 80% state of charge if there isn't enough solar power. I have mine at 30% throughout day and night to shave off the electricity bill as much as possible (our power outages are not as problematic anymore, so never been out of utility power for months now). Also, if you have a bi-directional meter, you could benefit from exporting excess power to the grid whenever it is available. The bi-directional meter will run in reverse, therefore giving you kWh credits. So even if the utility does not buy from you, you actually get to benefit from the kWh units anyway, so nothing to lose there.

MelvinPhuti
Автор

Hi drsolar i have same model of inverter with your video and i have a trouble when i connected grid, all consumtion load comes from grid not with panel and battery please help

munyannyan
Автор

In the manual it says 13 + 13 Amps max for the PV power. 8 panels in one string looks fine, but you can also put 5 + 5 panels in two strings to PV 1 and 2. Another option is to overpanel the inverter more than the rated Wattage. In case of full sunshine and 12 panels 550w each the energy over the rated inverter Wattage shall be clipped and can't be used. But this happens only at rare situations. But pls. confirm this with the manufacturer and your contractor installing the system.

gerdbeutler
Автор

Hello from South Africa. I am getting the Deye 8kw hybrid inverter soon due to load shedding.

colin
Автор

Hello, good video. Could you tell me how do you configure lifepo battery ?

nicolasfaure
Автор

2:40 So what exactly does that 30% mean for the grid? Does it mean that the grid will maintain a 30% minimum charge for the battery? And the solar panels will still be the ones to take the battery to 100% (outside of the System Work Mode settings)?

jp
Автор

What is the difference of Deye to Sunsynk and Sol Arc inverters?

billbreaker
Автор

Another great video - thanks. Can this be done on a mobile phone?

tonyosime
Автор

Hi, i bought 5kw Deye and 4x405w jinko mono panels - no batteries.
I mounted solar panels to a tiled roof and inverter in the house - the inverter supply my house with solar + grid (hybrid on high loads and solar only on small loads). The problem is when grid goes off the inverter gives error F47 - even though i connect small loads. Your answer will help a lot - currently budgeting to buy 1x3000C polytech.

nicomoloi
Автор

Thanks for the educative post. Well I am using the deye as purely an Inverter charger. Do I set it to Battery first or should I set to to Load first? Somehow I failed to interpret the modes. Basically am using batteries and Grid.

mwimafazal
Автор

How to set the deye hybrid to use only the battery as backup during brownout only?

guillermoolano
Автор

can you disable sell back to the grid.

enriquejoveslulu
Автор

From what I could gather reading the system work mode you basically grid charging the batteries from the grid during 0 sunlight hours and when the sun is out you have "de selected " the grid check box making the solar work to charge the batteries. Have I made an accurate assessment? Looking forward to any feedback from you

Xxxcappie
Автор

Hello. I did everything you mentioned. basically i want solar and battery to charge in Day and use Grid to charge the battery by night. I ticked it like your settings. Still the grid is charging the battery and load during the day.

CrimsonAlchemist