How to solve 88 Error in Haier Inverter Air Conditioner

preview_player
Показать описание
Haier dc inverter air conditioner 88 error show on display solve error in Urdu
Inverter ac error troubleshooting
How to find fault inverter ac 88 error
General Electronics HVAC
Рекомендации по теме
Комментарии
Автор

Hello

For those who are trying to fix the problem you have 2 stages for diagnosis, this is how :

Stage 1 :

Check the distribution box for faulty elcb if it's fine go to next step if it's not replace it, if the elcb is fine check the ac switch power should go to line wire from both sides .

Stage 2 :

If everything is fine, then you have to remove pcb from spilt ac and inspect damaged parts like broken shorts, bad resistor's, bad diodes, blown capacitor, blown fuses, broken or loose wires .

I just fixed mine by replacing broken shorts in the pcb and now everything just work's fine .

I hope that helps someone ..

crip
Автор

Indoor ac k andr ka transformer ka price kitna hoga kitne me change hoga?? 88 error aa rha

madhurdixit
Автор

Sir Mera Ac Orient Ultron 1.5 ton (Inverter) jab light chali jati hai, air dobara say ajati hy tu Automatically ON nhi hota. Mujy har dafa Manually Remote say usko ON karna parhta hai.

Means K agr light rat ko 10 bar jae aur ajae tu mujy nend say kag k usko remote say ON karna parhta hai ( jo k bht problem hai).

Iski reason air solution kia hai?

kamikhan
Автор

hi sir
i have a haier inverter aircondition at the start the indoor unit works normal the operation lamp is steady and the fan works
when give command to outdoor unit the operation lamp is blinking the blinds close and the led 1 of outdoor unit is light steady which mean all are ok with outdoor unit i havent any blinking code
do you have similar experience ?

dimitra.d
Автор

Changhong ruba ma same error ha koi hal bataen mane ye trick apply ki thi lekin koi fark nahi para

yousufshah
Автор

Bhai jan waporeter say la kar outdor pipe tak ice arahi ha lakin band kar ka chalaya 1ghanta bad to sub thek hota ha kiya ho sakta ha indor blor b sahi ha koi erer b nahi ha samsung ka unit ha

alltechnicalwork
Автор

Hy rizwan bhai kiya haal ha man wohi hon jo ap say namber.mangta rahta tha 😜😜

alltechnicalwork
Автор

bhai mera haier ka ac jab wapda jany k bad wapis ati hai to auto on nahi hota.remote sy bar bar krna padta hai.kia problem hai?

Sameerrayyan
Автор

88 error display mitsubishi how to fix it?

vochemindagnal
Автор

Bhai voltage sahi aa rha hai 216 voltage aa rha fir bhi 88 error code aa rha hai media

samshad
Автор

i have voltas 183 dzz non inverter ac its have error 88/rt, how to i solve it.

secondarysection
Автор

Loyyd non inverter AC indoor outdoor on hai cooling bhi Aa Raha hai par display me 88 ka error dekha Raha hai .. prblm Kya hai ?

syedsaleem
Автор

Nhai bhai voltage bhe thek ha phr bhe 88 arha ha HR 2 gante ke bad band kr ke chlao tu chal Jata ha

maliknomannoman