Hydrogen Vent Tamer Tutorial | Oxygen Not Included

preview_player
Показать описание
Taming a 500 degree hydrogen vent.

End Screen music: When Johnny Comes Marching Home by Cooper Cannell

---
Coordinates: V-SFRZ-C-469570110-8VW3

Mods:
Show Building Ranges by Stephen
Bigger Camera Zoom Out by Cairath
Pliers Fixed by oDr4gONo & pt_djefferson(Rus)

Рекомендации по теме
Комментарии
Автор

The 500°C is actually quite great. Too bad it's gas so it actually doesn't have much heat energy. But you can use this to turn crude oil into petroleum without risk of overheating it to sour gar. But like said, the vent won't have much heat energy and even a tiny amount of oil will just soak all the heat from it. Still early on this is one of the easiest ways to get oil turned as it doesn't require steel nor plastic or any of the space materials.

ShadowManceri
Автор

Much like eric said its overkill for this vent. its either going to get burnt off vented into space or turned into liquid. Pre cooling it for liquid is pointless as its so cold in that set up it insta drops.

2nd thou is if that pump ever back up the vent will stop emitting thus you lose resources. The all time best set up to tame a vent and never get backed up is to use the same size area but you seal off the pump with a vertical 3 door compressor. moving all the gas from the vent to the pump keeping the vent in a vacuum.

mtownley
Автор

Great video! Helping me out in 2025! TY!

RedBombX
Автор

You could also just not tame it and directly feed it into a hydrogen generator but you would lose a lot of energy from the heat that way.

malur_
Автор

I literally just dug the smallest hole and put a gold amalgam gaspump idk why but it never gets pass 120°c

blacklight
Автор

Why bother to bring pipes all the way up if you brought heavy wat wire downstairs anyway?

norbert
Автор

I lost you on the aquatuner bit. Is the aquatuner taking the steam to steam generator and bringing water back to the steam room to become steam after absorbing heat from the hydrogen geyser? Does that mean the steam generator is not putting out heat around it?

Abster
Автор

You kinda sound like Carl's sims guide

alonsogutierrez
Автор

Great tutorial, nice solid setup!
However the setup is rather expesive, I think your system can handle 5 more hydrogen vents :D

Cooling 98, 5 g/s of hydrogen from 500C to 125C is only 88, 6 DTU/s of heat that needs to be removed, less then 8 wheezeworts of cooling.

victorelfring
Автор

I can see mickey mouse delivering water to that room....

Verdekiwi
welcome to shbcf.ru