More info about STC-3008 temperature controller:

Setting method: Start value lower as stop value (program automatically determines working mode is heating mode)

Setting method: Start value higher as stop value (the program automatically determines the working mode is cooling mode)
Рекомендации по теме
Комментарии
Автор

Hey guys and girls. We need to be clear. Surely, this is a thermostatic "relay" device. So, it has two sets of controls (upper and lower temp switching) each for 2 relays (connecters 7->8, connectors 9->10) (Max. 220V AC to a heater, Max. 220V AC to a fan, connectors numbered 7 and 8, 9 and 10). YOU MUST NOT PUT LIVE AND NEUTRAL INTO THE CONNECTORS. The relay only switches through like a normal single pole light switch!

The connectors 1 and 2 (power supply) must be 12V DC (A battery should be enough to power the device, the relays and the LCD display.

The connectors 3 and 4 (activating a heating element or fan) will be the low temp sensor, the connectors 5 and 6 will be the high temperature sensor (activating acooling fan or refrigeration unit).

This device must only switch a single wire to each unit. CONNECTING both wires (e.g. LIVE AND NEUTRAL) will damage or destroy the device - and presents a fire or electrocution hazard!

It would be great to hear back from people to either confirm or deny my analysis.

Thank you.

ulicadluga
Автор

Great, Thank you. Captions are great but some audio (voice) would be even better.

paulfairlight
Автор

hello great video, do you know if it is possible to set both outputs to heat? or does out 1 heat and out 2 cool?

cristianomariani
Автор

كيفية تركيب الاسلاك

لدي نفس الجهاز v 12

هل يشتغل علي 220 v

medoooo
Автор

I have a water solar panels on the roof top and geyser tank at the bottom, using in-line pump to circulate the water during the day and off in the night can I use this temperature controller please advise thanks 😊

gregviegas
Автор

Can I use it so that it only activates when I go out of a specific temperature range?
sensor 1 < 10 degrees will activate the 1 relay
sensor 2 > 40 degrees activates the 2 relay

VacuumInfinity
Автор

What is the difference between the bule and red digital

mubarakNsser
Автор

Can we use to control heat pump machine? For swimming pool water heating purpose

Ganeshm
Автор

Salve, ho lo stesso apparecchio alimentato a 12v. E possibile su una uscita di un relè alimentare qualcosa a 220v o bisogna comunque collegarli prima un inverter di tensione? Ho bisogno di alimentare a 220v un riscaldatore per acquario che va a 220v, mentre per raffreddare uso ventole a 12v. Grazie anticipatamente.

gennaromigliore
Автор

Can you please help me how to connect it to my home made incubator ?

wakissamunthali
Автор

When you Like use both to cool or both to Heat.. try to play by invert high level temp and Low Level temp of each Channel. It works !

MetrakitProRaceII
Автор

Odwrotnie, czerwony chłodzi a niebieski grzeje.

dzikiwonsz
Автор

i cant get mine to deliver output. is there anything special one must do with the wiring

Andrew-hdpe
Автор

Will this controller plug into 220 AC to temperature switch and control a 12v 100w ceramic motorhome heater?

Thanks very much.

ulicadluga
Автор

Can you change the cooling function to a heating function?

Andrew-hdpe
Автор

Is it possible to put the red temperature in the same mode as the blue temperature!?

Ale-zqjx
Автор

Добрый день.Если питание 12 вольт, где + и -? Нигде найти не могу, если кто знает, подскажите.

jijgwfc
Автор

As it's 12 dc, does it require 12dc power adaptor or can be connected directly to power.??

nikhileshrk
Автор

It is possible calibrate the temperature of the two probes when the value are wrong?

marcofilippini
Автор

Может кто знает, почему показания не стоят на одной величине, а бегает на 8-5 показаний то в плюс то в минус. Короче не держится на одном значении. Почему?

qghmoge