strength of rcc column depends upon (voice by11.ai)

preview_player
Показать описание
strength of rcc column depends upon
your quary
rcc column
column design
design of rcc column
rcc column design
column
rcc column size
column load calculation
column load
design of column
column strengthening
rcc columns
design of rectangular column
rcc column construction
when strengthening of rcc column is neede
rcc column repair
rcc column jacketing
design steps of rcc column
rcc column size for 2 storey building
rcc column size for 3 storey building
size for rcc column
rcc column in house
Рекомендации по теме
Комментарии
Автор

iska detailed long video maine apne channel pr upload kiya hua hai aap chahe to dekh skte hai

deepakpal
Автор

Meanwhile Desi Mistri : Hold my beedi bundle kid

abhishek_sadotra
Автор

Steel rebars is used for tensile strength, not for compulsive strength

divyanshameta
Автор

If our column is under reinforced, then there is lack of ductility, , by which structure collapse.
If columns are over reinfocred, then it result in less ductility more stiffness

sahilsen
Автор

Jitna jyada loha hoga utna majbhot hoga q ki loha cement se jyada majbut hota hai jitna jyada size utna jyada loha aur cement jyada Kam kare aur loha badha te jaye jitna Kam loha hoga utna jyada cement se Kam jyada loha hoga utna hi badiya majbuti milegi aur achhi khasi cement Kam jyada karte jao aur Loha badate jao utni majbuti milti rahegi👍😊

pratikmevada
Автор

Nayi technology lao bhai, aaj ke chemical waale cement aur mitti ki eent se achhe to purane ghar hote the... 😅😅

RitikVermaOriginal
Автор

Absolutely right sir u r voice is incredible

amolnirwan
Автор

Please make full construction video series

satishchavan
Автор

if reinforcement is more...chances of brittle failure is increase which cause sudden damage of structure

Arun_singh
Автор

It is not that a coloum strength is independent of Reinforcement. Reinforcement is also important.

Abhibdps
Автор

Jitna bda column hoga utna jyada steel. Bat to same hi hue.

aarnaconstructions
Автор

Sir ductile detailing codes me sara concept revise ho gya hai

uttamhindustani
Автор

जय श्री राम भाई हम भी मिस्त्री है आप कहां से बोल रहा है जय श्री राम बहुत बहुत धन्यवाद आपके लिए यह बताने के लिए

ajaykori
Автор

Jyda steel ho to jyada load leta hai bas minimum area 0.8 percent and maximum area 6 percent
Pu=0.4 fck Ac+0.67 fy Asc

abcd-xlfe
Автор

Steel sariya company walo ki to nusan ho gai

haideransar
Автор

Bro size depend nai karta steel ziyada huna chiye

justmymemories
Автор

0.8% se kam or 0.6% se Jayda samajh me nahi aaya..

mdtausefali
Автор

Humko y lagta h ki collumn and beam m steel bars ki strength itni honi chahiye jitna ki agar beam colloum ka agar saara cement mortar agar gira bhi diya to steel rod m upper building ruk sake ...nahi to beam collumn m steel rod kya ukad aur steel bar to lagta h kahi na kahi column ki strength kam hi karti h ....example agar 1 feet column ki lxb 1x1 h aur wo without steel rod ki dusri taraf 1x1 m 8peice steel rod use kiye h to batao kon si strong hogi....mere khayal s to bin steel wali m concrete k binding achi hogi.. aur steel rod to binding concrete ko divide kar rahi

TulsiChand-yqwn
Автор

😳😳😳😳😳 तो लोग हमेशा मोटा सरिया ही क्यू लगते हैं

KuldeepKumarBansal
Автор

Why there is no brick construction below the beam

accountarrrrt
visit shbcf.ru