This is the first in a series of three videos explaining the Victron Energy Lynx range of products. Johannes talks about the Distributor and the Power In in this episode, how they differ and what are the benefits of using them over standard busbars.
#victron #busbar #victronenergy

00:00 Introduction
00:29 Victron Energy Lynx Power In
01:46 Victron Energy Lynx Distributor
Рекомендации по теме
Комментарии
Автор

This kit is excellent and i use it on my boat. If you don't need the extra functionality of the Lynx Distributor then you can buy the correct size bolts/washers etc for the Lynx Power-in which allows it to also be used with fuses etc... much cheaper than the Distributor.

robtheplod
Автор

I really love victron products. Pray to have some to use in the future...

mickeysherman
Автор

Since we will be charging the 48V /51.2) V battery with solar panels (4 x 480W - Vmp = 37.10, lmp = 12.95A), we would like to have exact information on which Victron MPPT controller is suitable so that the battery will be charged properly (Operatin value charge 43 -58V). Does the Victron 150/45 match the charging voltage? Can the such battery be charged from 200V with a charger, and if so, with what kind?

adamsisernik
Автор

I won't consider anything else than Victron Energy in my next home for a Solar Power System, as I can see everything is purpose built & very well designed for Home, Boat, Van, Car etc well Done Victron Energy for a quality products, (Retired Aerospace - Defence Electronics Hardware Qualification Verification Test Engineer) I know Quality when I see it 👍👏
Philip

CoolMusicToMyEars
Автор

Very nice piece of kit, makes job way faster especially with many batteries 🪫 or many chargers on the system . Lynx power in can be easly transformed to mega fuse holder . It takes 4 bolts n nuts to make it hold 4 mega fuses . Very neat job

mattd
Автор

Does the lynx power in only work with lead acid batteries ?. Or also lithium

senogamoses
Автор

I really like the Lynx series of devices and I use them in my PowerWall setup. The only feature Victron need to fix, is that the Lynx Shunt currently does not display any DC power in the Consumption summary near the graph (VRM). So, AC power is perfectly shown and added to the Consumption tile, but the Lynx Shunt totally ignores any DC power.
However, that works perfectly fine with the Smart Shunt and the BVM. Both show AC and DC power combined in the Consumption tile. So, I assume this is just a software update away, hopefully coming soon!?

(I have read the discussion on the community forum about this feature and many are waiting to actually start using this 'expensive fuse holder', as some refer to it.)

OffGridGarageAustralia
Автор

I got the Lynx Distributor because I needed a rock solid fused busbar. I do love it for that! Am slightly disappointed it's dumb w/o the BMS (which is expensive).

keithwingo
Автор

2:12 The Lynx distributor data doesn't seem to be sent to the Lynx shunt as stated in the video. The individual fuse status doesn't show up in the Victron Connect app. From what I've read, this is only available when using a Lynx BMS. Is this true? Are there any plans to make the data available for the Shunt?

AdamDeLay
Автор

I have two Lynx Distributor installed and between them the Lynx Shunt, but I can not see the status of the fuses in VRM. Is it necessary to have the Victron BMS as well?
I ask because Johannes said BMS or Shunt.

dennyalbert
Автор

In Australia and New Zealand we have to fuse the positive AND the negative legs. From what I can see on the Distributor, it only has a fuse on the positive leg correct? Do you have some solution or idea how to easily get the negative leg fused as well? Thanks

bruvalee
Автор

I have no idea how to wire power supply...it says the RJ10 need to go to a VE CAN...but my leds are still off. the manual does not explain more. there a re videos here explaing the power source for the distibutor 1000. very strange! Please explain this. thx

ginstuttgart
Автор

Can we ever expect a LYNX distributor that uses class T fuses? We sure could use it here in the states for LiFePO4 batteries. There are mods that have been done so it can be done—at least to the power-in without fuse monitoring.

A couple of other “wants”: a module which includes a mechanical disconnect switch; a low power connection (12-16 #10, 1/4” posts with ATO and maxi fuses); a 1000a LYNX BMS; 90 degree modules (left and right)

I love the concept—please expand it!

jimduke
Автор

It is a really nice system. I considered it as one of the options. Also the tigerexped ufo was an option. But I choose a DIY solution with a 35 euro Victron 250A 6x mega fuse box. And I put my phoenix 2000va compact on a separate busbar.

I think the lynx system is great but also it becomes pretty expensive if you need more then 4 mega fuses. Also for alot of things a 1000A busbar is not needed. So I think there is a place for a cheaper module with a smaller rated busbar and mega fuses. So for most DC-DC, Solar etc you need 40 to 80A fuses.

Or maybe develop a budget lynx line for small to medium systems.

Victron is my main choice and I love building with Victron components. Yesterday I updated the firmware on my phoenix 2000va compact (1908 small cpu) and I programmed the relay function for extra cooling. And I also got the remote switch panel working 💪😁

unimog
Автор

I'm planning on applying liquid metal from CPU side of things. To ensure surface contacts over my lynx distribution system & for all fuses et cetra.

patricklyons
Автор

Hola johannes eres unas de las pocas caras visibles que puede ver en la red, espero que ka vida te trate bien, he visto muchos videos tuyos, pero se que detrás de la marca que representas hay un gran equipo, quiero agradecer todo buestro trabajo, ya la marca por dedicar tanto trabajo y esfuerzo para producir equipos tan buenos 👍

mflo
Автор

should you ground the busbar as well in a ESS ON grid system ? would a 6 mm grounding cable be enough to be connected to the House Ground system ? (PE)

patrickmaartense
Автор

Hello, this is not like my installation. i have 2 distrubutors and the lynx shunt but can't configure or view the fuses here. 3:06

Rikkert-RS
Автор

Can you change the name of the power into just DC Power as I used it as a positive busbar and another as a negative busbar.

chuxxsss
Автор

Unrelated but are there plans to be able to assign different battery types in the multi channel IP chargers? Ie IP22 and Phenix IP 43 chargers, bank 1 lead acid, bank 2 agm, bank 3 lithium?

andrewhoughton