Feature spotlight | INTELLiVENT-ASV on HAMILTON-C1/T1
Показать описание
Individualized, lung-protective ventilation with INTELLiVENT-ASV
With the introduction of INTELLiVENT-ASV, the most advanced ventilation mode from Hamilton Medical is now available on HAMILTON-C1 and HAMILTON-T1 ventilators. The graphical user interface of this ventilation mode has been optimized for the compact display on these devices.
INTELLiVENT-ASV continuously applies individualized, lung-protective ventilation by selecting safe driving pressure, safe mechanical power, and safe tidal volume (Arnal 2019). It ensures that the patient spends more time in the targeted oxygen saturation range, a measure considered protective against hypoxia (Bialais 2016) and hyperoxia (Arnal 2019, Bialais 2016).
If you are already using INTELLiVENT-ASV with other Hamilton Medical devices, you can now provide a continuum of care in all situations, including during transport.
Clinical studies show that INTELLiVENT-ASV:
-Requires fewer manual adjustments than conventional ventilation, consequently reducing the workload for the healthcare team (Bialais 2016)
-Is rated as having the most technological capabilities of all evaluated modes in terms of safety, comfort, and weaning (Mireles-Cabodevila 2013)
-Follows the latest recommendations for lung-protective ventilation in terms of tidal volumes and driving pressure (Arnal 2019, Arnal 2016)
References
Arnal, J.-M., M. Saoli, and A. Garnero, Heart & Lung: The Journal of Cardiopulmonary and Acute Care. 2019 Nov.
Arnal JM. Intensive Care Med Exp 2016, 4(Suppl 1):A602.
Bialais, E., et al., Minerva Anestesiol, 2016. 82(6): p. 657-68.
Mireles-Cabodevila E. Respir Care. 2013 Feb;58(2):348-66. *Erratum in: Respir Care. 2013 Apr;58(4):e51
The availability of SW v3.0.x, as well as individual features, depends on the specific device and market. INTELLiVENT-ASV is currently not available in the US (May 2021).
The HAMILTON-C1, HAMILTON-T1, and HAMILTON-MR1 ventilators are our most popular devices. Combining big performance with a compact size, these three ventilators are ideal companions for all patient groups in different applications. The software update v3.0.x brings many new features* and improvements:
- New graphical user interface (GUI)
-Individualized, lung-protective ventilation with INTELLiVENT®-ASV®
- CPR ventilation
- Upgraded high flow oxygen therapy
- Volume Support mode
- Digital solutions for respiratory care: Hamilton Connect Module and App
- Remote access to HAMILTON-H900 controls and status
- Greater visibility of TeslaSpy alarms
*Not all features are available in all markets.
To never miss any news, follow us on:
With the introduction of INTELLiVENT-ASV, the most advanced ventilation mode from Hamilton Medical is now available on HAMILTON-C1 and HAMILTON-T1 ventilators. The graphical user interface of this ventilation mode has been optimized for the compact display on these devices.
INTELLiVENT-ASV continuously applies individualized, lung-protective ventilation by selecting safe driving pressure, safe mechanical power, and safe tidal volume (Arnal 2019). It ensures that the patient spends more time in the targeted oxygen saturation range, a measure considered protective against hypoxia (Bialais 2016) and hyperoxia (Arnal 2019, Bialais 2016).
If you are already using INTELLiVENT-ASV with other Hamilton Medical devices, you can now provide a continuum of care in all situations, including during transport.
Clinical studies show that INTELLiVENT-ASV:
-Requires fewer manual adjustments than conventional ventilation, consequently reducing the workload for the healthcare team (Bialais 2016)
-Is rated as having the most technological capabilities of all evaluated modes in terms of safety, comfort, and weaning (Mireles-Cabodevila 2013)
-Follows the latest recommendations for lung-protective ventilation in terms of tidal volumes and driving pressure (Arnal 2019, Arnal 2016)
References
Arnal, J.-M., M. Saoli, and A. Garnero, Heart & Lung: The Journal of Cardiopulmonary and Acute Care. 2019 Nov.
Arnal JM. Intensive Care Med Exp 2016, 4(Suppl 1):A602.
Bialais, E., et al., Minerva Anestesiol, 2016. 82(6): p. 657-68.
Mireles-Cabodevila E. Respir Care. 2013 Feb;58(2):348-66. *Erratum in: Respir Care. 2013 Apr;58(4):e51
The availability of SW v3.0.x, as well as individual features, depends on the specific device and market. INTELLiVENT-ASV is currently not available in the US (May 2021).
The HAMILTON-C1, HAMILTON-T1, and HAMILTON-MR1 ventilators are our most popular devices. Combining big performance with a compact size, these three ventilators are ideal companions for all patient groups in different applications. The software update v3.0.x brings many new features* and improvements:
- New graphical user interface (GUI)
-Individualized, lung-protective ventilation with INTELLiVENT®-ASV®
- CPR ventilation
- Upgraded high flow oxygen therapy
- Volume Support mode
- Digital solutions for respiratory care: Hamilton Connect Module and App
- Remote access to HAMILTON-H900 controls and status
- Greater visibility of TeslaSpy alarms
*Not all features are available in all markets.
To never miss any news, follow us on: