💡 How does false signal suppression work in a level sensor? | VEGA talk

preview_player
Показать описание
📱 In this episode of "VEGA talk" the topic is false signal suppression. If there are installations in the tank, for example an agitator, they can interfere with the level sensor readings. The sensor will detect the false signals in addition to the actual level echo. These false signals can be blocked out, mapped or suppressed, directly in the sensor via PACTware or the VEGA Tools App.
However, thanks to the 80 GHz technology used in the VEGAPULS 64 and VEGAPULS 69 radar sensors , such interfering signals are virtually eliminated. They have extremely good focusing, which enables the level sensors to simply avoid any interfering reflections from fixtures or buildup and deliver a reliable process measurement.

📢 More information about our sensors:

📢 More information about level measurement with radar sensors:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

🔔 Subscribe to our channel and you'll never miss a video:

📱 Follow us on LinkedIn:

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Would you like more expert tips and news on level and pressure measurement technology?

📒 Visit our blog:

🎯 Discover solutions for your industry:
Рекомендации по теме
Комментарии
Автор

Theres a level deviation between a remote seal and a vega 65 puls radar at the plant i work at. Could it be a false signal suppresion?

drewshearman
Автор

should the ajustment be done on the place of operation pra could i just do It on the lab and after installing on the process?

ygordavid
Автор

Dears, we are using vega plus64 radar type transmitter.The problem is, during dosing H2SO4 and H2O2 in vessel transmitter giving wrong reading, otherwise its going 100%.
N:T: vessel has agitator and during dosing chemicals temperature is 53deg c.
We have more than 30 transmitters facing this issue.
Tnx

MdEmon-txsk
Автор

Hello what is Vega Good for measurment level liquide chimique or tanks

yveskoutouan
Автор

Can we do false signal suppression when some level is there?

lokeshloki
Автор

What happens when the false signal suppression changes on its own? And cause this to happen?

eugeneharrelson
Автор

I use VEGAPULS C 21, How do I do a False Signal Suppression?

MrSinestesico
Автор

@vegagrieshaberKG we are using vegaplus 64 ....sometimes LT showing 0% even level is there....what was the problem?

lokeshloki
Автор

this topic needs more examples, two minutes is just not enough.

Timeyes
Автор

Vegabar 38 sensor. F111 error Unlock adjustment code required

ponnuranganrangan
Автор

I was expecting an example of a demonstration, not a talking face

pavelkrajtl