Met One Instruments, Inc., E-SEQ-FRM
Показать описание
Sequential Reference Particulate Sampler
-All mechanical, non pneumatic
-Multi-event, sequential sampling of ambient air onto filter media
-US-EPA PM2.5 Reference Method (RFPS-0717-245)
-US-EPA-PM10 Reference Method (RFPS-0717-246)
-US-EPA PM10-2.5 FRM Reference Method (RFPS-0717-247)
-Korea Certification (APSC1-2016-01)
-47 mm filter For US-EPA PM2.5 and PM10-2.5 sampling: Teflon 2µm pore size membrane filter
(regulation required). For US-EPA PM10 reference sampling Pallflex TX-40 quartz filter and Teflon media
-Active flow control for 16.67 LPM. Sampled volume reported under actual and standard conditions
-Temperature, barometric pressure and multi-point flow
-More than 130 days of interval data with 5 minute time resolution 132 filter records
-Keypad/display for data retrieval and programming. RS232, USB serial and USB flash drive interface for data download
-Negative 40°C to positive 50°C
-100-240 VAC 50/60 Hz 1.4 amps
-System/Pump: 14.4 (w) x 14 (d) x 27 (h) Stand (at base)
-24.5 (w) x 23.5 (d) x 29.6 (h) Total (at base) 23.5 (w)x 24.5 (d) x 56.6 (h)
-System/Pump 45 lb
-Stand 10.5 lb
-PM10 Inlet 5.3 lb
2020/01/10 - Remember to update your operator's manual to revision E
2020/01/10 - Current main firmware is R1.4.6
Contact us with any questions, comments, concerns. The friendly crew at Met One Instruments, Inc. welcomes all to come train at our factory in Grants Pass, Oregon USA free of charge.
+1-547-471-7111
-All mechanical, non pneumatic
-Multi-event, sequential sampling of ambient air onto filter media
-US-EPA PM2.5 Reference Method (RFPS-0717-245)
-US-EPA-PM10 Reference Method (RFPS-0717-246)
-US-EPA PM10-2.5 FRM Reference Method (RFPS-0717-247)
-Korea Certification (APSC1-2016-01)
-47 mm filter For US-EPA PM2.5 and PM10-2.5 sampling: Teflon 2µm pore size membrane filter
(regulation required). For US-EPA PM10 reference sampling Pallflex TX-40 quartz filter and Teflon media
-Active flow control for 16.67 LPM. Sampled volume reported under actual and standard conditions
-Temperature, barometric pressure and multi-point flow
-More than 130 days of interval data with 5 minute time resolution 132 filter records
-Keypad/display for data retrieval and programming. RS232, USB serial and USB flash drive interface for data download
-Negative 40°C to positive 50°C
-100-240 VAC 50/60 Hz 1.4 amps
-System/Pump: 14.4 (w) x 14 (d) x 27 (h) Stand (at base)
-24.5 (w) x 23.5 (d) x 29.6 (h) Total (at base) 23.5 (w)x 24.5 (d) x 56.6 (h)
-System/Pump 45 lb
-Stand 10.5 lb
-PM10 Inlet 5.3 lb
2020/01/10 - Remember to update your operator's manual to revision E