EasySeal Direct Inject - How to Easily Seal an A/C Leak

preview_player
Показать описание

EasySeal Direct Inject features a patent pending injection method that makes it extremely easy to install. With this new injection system, there is no need for pumping down the unit. When injected, EasySeal travels with the refrigerant, searching for and sealing the smallest of leaks in condensers, evaporators, copper lines & soldered joints. It reacts with moisture and air that are naturally present at a leak, forming a secure seal. With A/C EasySeal, the technician is able to inject to the system and be confident the leak has been fixed and move on to the next job. EasySeal Direct Inject treats 1.5 to 5 tons.Features & Benefits:•Works with all refrigerants and oils.•Concentrated formula means less material in system.•Clear tube so you can see the sealant go in•No need to pump down R-410A units.•Perfect for split systems, heat pumps, microchannel coils, packaged units, and mini splits•No injection hose or caulk gun needed•One time use•Treats 1.5 to 5 tons
Рекомендации по теме
Комментарии
Автор

This music is making me feel like the badass service tech that I know I can be

TR-rfjv
Автор

In this example, you should have used a common manifold with blue, red, yellow lines ... so, it would be clear that the yellow line is attached to the direct eject tube.

packjtw
Автор

party boy put the background music on this nightclub AC product

YouTubeUserToo
Автор

I've used easy seal on 7 systems with 0/7 leaks stopped. I know of countless other techs that have used this before, but to my knowledge it has never stopped a leak. Scam maybe?

jervislove
Автор

I used this stuff and it worked great. Got some more time out of old unit.

marksini
Автор

I’m picking up 2 of these tomorrow, how am I supposed to purge the lines prior to injection?

MrWontstopthefunk
Автор

How do you PURGE the gauges and lines???

As soon as it's connected everything goes right in the system unpurged AIR AND MOISTURE!!

seriously what about this how to avoid??

jfmc
Автор

Everyone who uses this is making a mistake this can clog your capillary tubes and your needle inside of your TXV and it causes more problems than what it's worth and this is coming from a guy who has over 17 years of experience dealing with this crap. And then you don't know if you're refrigerants contaminated because so many people working on the same AC and if you don't charge with pure liquid for example if you charge with the bottle right side up you're not actually charging the unit with all of the mixtures of each gas you're not getting a concentrated mixture you're only getting one or two of the gases. This causes problems because the gas mixture is no longer the same as it is when you charge liquid the best thing to do is remove all the old refrigerant replace the dryer Purge and vacuum with nitrogen two or three times then charged with 100% new liquid refrigerant bam problem-solve you're welcome

caseyparish
Автор

What if Nitrogen has been pumped into the system to check for leak? Will this work with nitrogen?

gfriedman
Автор

Don't miss out on the "Original" and very first A/C Stop Leak, the one that was originally developed for the government 30 years ago and then later offered to the HVAC service industry. ACT is simply the best because it is simple... Multiple high tech oils blended with propriety pre-manufactured micron-sized soild particulates. Of most importance though... it is "Not an activated product" like all the others. Just read the manufacturer's explanations of how they work and you will discover it is a "Reaction to moisture upon exiting the system and subsequent hardening that forms a patch on the exterior of tubing". What ??? The first question would be, how does it not likewise react to moisture "inside" the system? The second question should be, how does a "liquid" product exiting the system at velocity make a 180 degree turn around and then come back to the surface to create a hard patch? I would think this idea fights the laws of physics but hey, maybe they have figured out a way to beat these laws. Honestly, what happens is they harden "inside" the system and the resultant blobs float around until they stick in a hole, or worse, they clog a valve an orifice or a cap tube. The worse part is these "alternatives" are expensive when compared to ACT, actually about twice the price. Try the first and only real "non-polymer" A/C Stop Leak, but also benefit when it likewise lowers vent temperatures, kills acid, modifies water molecules, super lubricates the compressor, controls oil fouling, reduces compressor noise, lowers electric bills and more. Check it out and you will never go back to the Johnny come lately "copycats", we unconditionally guarantee it. www.stopHVACleak.com and www.134acStopLeak.com We welcome your comments and encourage you to try our revolutionary product, so you can learn the truth and facts concerning safely stopping leaks. Wholesale, factory direct to all installers, you will save thousands of dollars per season if you currently purchase as few as 20 treatments per year.

garyroy
Автор

I don't get it. Is this a one time use or what?

andygalindo
Автор

0:50 the tech's purging the air out of his hoses.

usahoangsatruongsa
Автор

I bought this on Amazon. Schrader valve will not open as reported in many comments below. No option to return on Amazon. You have to go through manufacturer who gives you the run around asking you to send emails and promises someone will contact you in 24 hours. A waste of time and money. Very disappointed with the manufacturer and Amazon. Will go back to EBay at least they support their customers. Do not buy this product if it is defective you are just out $40.

johnklinck
Автор

Fifty fifty with me before u waste money hit it with 120 nitrogen to indicate exactly n you be the judge in my career I've noticed it will help but if there is a leak to begin with we know as techs the unit weighted loss must be replaced if it's over a certain amount it will help u out of a bind but dont forget that it could pop back up n a series of units always go out when its 100 outside or 21 outside

troygensemer
Автор

Congratulations, you now have a restricted txv. But no leaks now after it.. lol..



Either that or next person to hook a set of gauges to the system if they dont purge first, they gonna have a difficult time reading with stop leak all up in their orificesusesis..

Z-Ack
Автор

If if isn't refrigerant it's a contaminate to me. Just pump the system up with nitrogen after evacuating the refrigerant and spray the coil or any joints with bubbles. Do it right and not with this garbage.

nealedmondson