Stripping down a Viessmann system boiler and Viessmann combi boiler. Today we've got two Viessmann boilers that I'm gonna strip down. So we've got 30-kilowatt Viessmann combi boiler here, which is a WB-1B. And then, we've got a 35-kilowatt system boiler. So what I'm gonna do is, I'm gonna strip these both down, and I'm gonna show you all the parts inside them.

This one is a 35-kilowatt WB-1C, so we'll strip that down as well. So I'll strip them both down, and we'll have a look inside them, and see all the components that you see in these boilers. So this video is aimed, really, at new recruits into the industry, just to give you an idea of what's inside boilers. It's not meant as any sort of training video. And always remember, if you work on any boilers you must be Gas Safe registered. So you have to Gas Safe registered to work on gas boilers.

First of all, what we'll do is, I'll just show you a little look around in here, just some of the other boilers that I've got on show. So have a look at that now. That's a Neo tech there, which I totally stripped to bits. We've got three Ideal Logics there. And then we've got the Viessmann ones there, which we're gonna take apart now in a few minutes. We've got a Vaillant boiler. We've got a Worcester boiler, a Worcester Bosch CDI that I've stripped down, and then we've got a new Baxi 600, again that's been fully stripped down as well. So all these boilers are just demo boilers, just for testing and cutting up and playing with really.

Then I've got all bits of ... So it's a total mess in here, just got all bits of boilers everywhere. Heat exchangers, expansion vessels. Right, okay, so let's get into these boilers here now and start stripping them down. So first of all to take the cases off on these boilers we've got two screws just under here. There's one on this side, and then there's one on this side here. On this one here they've already been undone, under there. Then all we need to do then, once you've undone the two screws underneath, you can just lift the case off. So there's the two boilers inside, so we've got a heat exchanger there, we've got the fan, and we've got the gas valve.

Then the same in that one, we've got gas valve, fan, and heat exchanger. So we've got this expansion vessel there, and then the same in that one as well. So what I'll do, we'll strip this one down now, and we'll have a look inside. So they're very easy to strip down, these boilers. So to take the burner DAR off here, we've just got some bolts to unscrew, just on here, four bolts. Then we've just got to undo gas valve and we've got to take electrical connections off on here and on the fan, so we'll do that now. So just to be careful on this because that's got your washer in there for your gas valve.

So that's obviously not been off for a while so I should imagine this hasn't been serviced since it were installed. So that's all your burner, your electrodes there look. So, if you want to strip one of these down, you check this seal in here, and then you may need to change that. You'd have to look in manufacturing instructions just to double check. Then lets have a look inside boiler. So if you have a look inside this, this clearly hasn't been serviced since it's been installed. So if we have a look at this one on this side, that's a lot cleaner, so that's obviously been serviced more often than the one on the left.

So now we'll take the heat exchanger out on this, so we'll just take off this hose. So I've removed the hose and there's just a few bolts to undo, so there's one there, one at that side at back, just there, and then one there as well, and then we can just unclip the back hose from there. Bear in mind this boiler is fully drained down, it's not connected to the system at all. There's also this pipe to come off on the bottom there. So I've undone the screws out the top of the flu here, just pull that out the way. Then that'll make it easier just to lift this heat exchanger forward. You see there, I'll just lift it out, if we can get all the wires off it.

We'll have a little look at that heat exchanger in a little while, first of all we'll take out the expansion vessel. Normally I'd use adjustables but this is not going to be put back together so. So just remove expansion vessel out of that. So in this particular boiler you've got an eight litre expansion vessel, in there. So to lift this bottom flap down, we've just got to clip in this side and we've got a clip in this side, and then that will just open down like that. Lift that out the way that we took off earlier. Then you've just got your pump in there, you've got your auto-air vent, you've got your blow off there, so if you needed to change that, you could just change that from there. Then you've got all your diverter in there, you've got a blanking plate there, so must be if that had a plate heat exchanger.
Рекомендации по теме
Комментарии
Автор

That was a simple yet very good look at how to expose all the components. Thanks again

jeffmcbride
Автор

Thanks for sharing your knowledge. I appreciate the way you repeat yourself at times to hi light things

jeffmcbride
Автор

Do you have a guide on how to service the diverter valve on the WB1B ?

dhutch
Автор

Great Video Allan. I liked the way those Viessmans come apart. Very good video

danielwilliams
Автор

Great video, thank you! Just curious, what is the black deposits in the unit that hadn't been serviced? I had mine cleaned a year ago, but then had a bunch of this stuff in there now, and just wondering what causes this. The technician says that in the past I didn't have it serviced often enough, and so it might be leaking?

davidalearmonth
Автор

Thankyou Alan....I have a vitodens 100-W to service this week and this has been very helpful as an insight 👏👏👏👏 they look very good to work on unlike many other cramped boilers. ⭐️⭐️⭐️⭐️⭐️

paulrossiter
Автор

Thanks. Handy to see how it works and very useful as I'm not sure our service guy does a full clean. Never seen him remove the burner as far as I can remember

twiggacott
Автор

Do you need to fit a new gasket, every time you strip down the burner on boiler

daviddavues
Автор

Mine is a Vitodwns 100, the upper housing is completely surrounding the inner parts, and also there is a plate separating the upper round heat exchanger together with gas connection, below the separator plate is the pump and the hot water heat exchanger, and in this model it is more difficult to take this hot water heat exchanger due to less space to maneuver, and i can not find the name plate of this model, iwould like to see the complete dissassembly of the specified model and maintenance, thx

bugz
Автор

hi what to do with the gas valve if it does not open?

goodlife
Автор

these look similar in layout to the baxi. I like that you have a near full cover to lift off, it gives me more confidence the housing will remain in tact.

gm
Автор

Hi Allen, All your videos are worth watching . keep them coming .

keithjackman
Автор

Hi Alan, how do you remove the trapon these? Ie to clean it? Can you do it from underneath?

MrGoonerguy
Автор

Could you show the best way to change the pressure relief valve in situ, cheers.

stevehouse
Автор

Hello Allan, thank you for taking the time to make the video. It was very informative. Good job.

yeknafaskesh
Автор

Good video.
I just out in a new vittodens 100 combi. Interesting to see that Viessmann continue to improve their product. Also good to see effect of not servicing a boiler.

daveramsay
Автор

I've got a 100-W 26kW Combi. The call for hot water seems to ignore the flow sensor, it's purely temperature based. Because of this it fires up several times in the night to heat the tiny amount of DHW in the plate exchanger and then turns off (all at zero flow). It's a really annoying. I've tested the flow sensor separately and it's all in-spec. Is this the intended operation of the boiler or is there a problem with the main board?

Mark_Won
Автор

Hi Allen, how much do you reckon should cost to replace AAV on one of these...it's leaking and letting by...

jonathantait
Автор

Hi Allan
I got viessmann combi boiler.F2 keep come. Can you do something about it.
Thank You.

shantilalpatel
Автор

Hi allan love your videos I am having problems with viesman viterdens 100 6 years old hot water is fine in sink but filling the bath warm not hot, I have watched the temp gauge it stays fairly low 50centgrade, any idea's I have had the heating engineer back but lost faith.

brucecarter